troubleshooting
Summary of the faults
S LEBHOOTING
d01 | Water supply fault (tap) |
|
|
d02 | Draining fault |
|
|
d03 | Heating fault |
|
|
d04 | Temperature fault |
|
|
d05 | Fault – motor under load |
|
|
d06 | Fault - motor overload |
d07 | Overflow / |
|
|
d08 | Sprinkling distribution fault |
|
|
d11 | Pressure sensor fault |
|
|
d12 | Filling fault (water inlet detection system) |
|
|
d13 | Overheating fault |
|
|
| Installation fault : (incorrect drainage |
d14 | Connection or inadequate flow rate and |
| tap). |
07TROU
If one of the above faults occurs and you need to call a repair man, remember to tell him the message displayed (d01, d02..) as this information will help him.
Before calling for service
Problem |
| Possible Causes | What to do? | |
|
|
|
| |
The door falls | • | Door springs not tensioned | • Tighten the two tensioning screws | |
heavily when opened |
| enough to compensate for the | accessible in the bottom section | |
(integratable model) |
| weight of the panel. | above the front feet. | |
|
|
| ||
| • Door springs tensioned too much. | • Loosen the two tensioning screws | ||
The door does not stay |
|
| accessible in the bottom section | |
horizontal when open |
|
| above the front feet. | |
or returns too quickly | • | No wooden panel. | • Fit a temporary wooden panel | |
(integratable model) |
|
| on the appliance and adjust the | |
|
|
| springs. | |
|
|
|
| |
The door catches when | • | Appliance not stable. | • Adjust the feet. | |
|
|
| ||
• | Door not centred on the tub. | • | ||
closing | ||||
|
|
| feet. | |
|
|
|
| |
The upper basket does | • | Poor manipulation (the basket is | • Act more progressively (see | |
not stay in the high |
| being pulled upwards too quickly). | instructions), one side and then | |
position |
|
| the other. | |
|
|
|
| |
Small leak around or | • | Leak from the tap. | • Check that a seal is fitted and | |
under the appliance |
|
| retighten the nut. | |
(move the appliance to | • | Leak from the appliance. (Cf. table | • Close the water tap and call a | |
locate the leak) |
| fault d07). | technician. | |
|
|
| ||
| • Appliance not stable or not level. | • Adjust the feet. | ||
Small leak at the door |
|
|
| |
• Door not centred on the tub. | • | |||
| ||||
|
|
| feet. | |
|
|
|
|
troubleshooting _23