Desa Tech CGD3930N, CGD3018N, CGD3924N installation manual Gas leak. See Warning

Page 26

TROUBLE-

SHOOTING

Continued

26

WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

Heater produces a

1.

Metal expanding while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burner is lit

 

while cooling

 

excessive, contact

or shut off

 

 

 

qualified service person

 

 

 

 

 

 

Heater produces

1.

Heater burning vapors

1.

Open window and

unwanted odors

 

from paint, hair spray,

 

ventilate room. Stop using

 

 

glues, cleaners, chemi-

 

odor causing products

 

 

cals, new carpet, etc.

 

while heater is running

 

 

(See IMPORTANT

 

 

 

 

 

statement above)

 

 

 

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement at top of

 

(see Checking Gas Con-

 

 

page

 

nections, page 17)

 

 

 

 

 

 

Heater shuts off in use

1.

Not enough fresh air is

1.

Open window and/or door

(ODS operates)

 

available

 

for ventilation

 

2.

Low line pressure

2.

Contact local natural gas

 

 

 

 

company

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

nance, page 23)

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warning

1.

Locate and correct all leaks

control knob is in OFF

 

statement at top of

 

(see Checking Gas Con-

position

 

page

 

nections, page 17)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during

1.

Foreign matter between

1.

Take apart gas tubing and

combustion

 

control valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement at top of

 

(see Checking Gas Con-

 

 

page

 

nections, page 17)

102986

Image 26
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Burner patterns can cause sooting Operation Local Codes Unpacking Product FeaturesSafety Device Piezo Ignition SystemProviding Adequate Ventilation AIR forVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRTion and ventilation air by one of the methods described Ventilation Air From OutdoorsInstalling Check GAS TypeMinimum Wall and Ceiling Clearances see Figure Minimum Fireplace ClearanceLOG Sizing Requirements Minimum Non Combustible Material Clearances Installing Minimum Non Combustible Material Clearances Log SetFloor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededMounting Bracket Connecting to GAS Supply Checking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Installing LogsOperating Heater Heater OperatingOperating Heater Inspecting Burners Pilot Flame PatternTrouble Shooting CleaningMaintenance ODS/PILOT and BurnerMaintenance, TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Model Technical ServiceService Hints Parts Central Parts Under WarrantyParts Not Under Warranty Hood GA6050 AccessoriesValve GA5010 Hood GA6052Illustrated Parts Breakdown Parts List CGD3018N CGD3924N CGD3930NWarranty Information Keep this Warranty