Desa Tech CGN20TL, CGN30TL installation manual TROUBLE- Shooting, Ing and Maintenance

Page 24

24

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

Burner does not light

1.

Burner orifice is

1.

Clean burner (see Clean-

after ODS/pilot is lit

 

clogged

 

ing and Maintenance,

 

 

 

 

page 22) or replace burner

 

 

 

 

orifice

 

2.

Burner orifice diameter

2.

Replace burner orifice

 

 

is too small

 

 

 

 

3.

Inlet gas pressure is

3.

Contact local natural gas

 

 

too low

 

company

 

 

 

 

 

 

Delayed ignition of

1.

Manifold pressure is

1.

Contact local natural gas

burner

 

too low

 

company

 

2.

Burner orifice is

2.

Clean burner (see Clean-

 

 

clogged

 

ing and Maintenance,

 

 

 

 

page 22) or replace burner

 

 

 

 

orifice

 

 

 

 

 

 

Burner backfiring

1.

Burner orifice is

1.

Clean burner (see Clean-

during combustion

 

clogged or damaged

 

ing and Maintenance,

 

 

 

 

page 22) or replace burner

 

 

 

 

orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Yellow flame during

1. Not enough air

1.

Check burner for dirt and

burner combustion

 

 

 

debris. If found, clean

 

 

 

 

burner (see Cleaning and

 

 

 

 

Maintenance, page 22)

 

2.

Gas regulator defective

2.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor

1. Residues from manu-

1.

Problem will stop after a

during initial opera-

 

facturing processes

 

few hours of operation

tion

 

 

 

 

 

 

 

 

 

 

Heater produces a

1. Turning control knob

1.

Turn control knob to LO

whistling noise when

 

to HI position when

 

position and let warm up

burner is lit

 

burner is cold

 

for a minute

 

2.

Air in gas line

2.

Operate burner until air is

 

 

 

 

removed from line. Have

 

 

 

 

gas line checked by local

 

 

 

 

natural gas company

 

3.

Air passageways on

3.

Observe minimum installa-

 

 

heater blocked

 

tion clearances (see Figure

 

 

 

 

4, page 10)

 

4.

Dirty or partially

4.

Clean burner (see Clean-

 

 

clogged burner orifice

 

ing and Maintenance,

 

 

 

 

page 22) or replace burner

 

 

 

 

orifice

103873

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationIf you smell gas Local Codes Unpacking Product Features Safety DeviceProduct Identification Piezo Ignition SystemFresh AIR For VentilationProviding Adequate Ventilation Fresh AIR Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Fresh AIR for Combustion and Ventilation Ventilation AIRVentilation Air From Inside Building Ventilation Air From Outdoors Ventilation Air from OutdoorsInstalling to Wall Installation ItemsCheck GAS Type Locating HeaterThermostat Sensing Bulb Locating Thermostat Sensing BulbAttaching Thermostat Sensing Bulb Bracket Marking Screw Locations Maintain minimum clearances shown in . If you can, provideGreater clearances from floor and joining wall Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Connecting To GASSupply Checking GASPressure Testing Heater GAS Connections CheckingFor Your Safety Read Before Lighting Operating HeaterOperating Heater Shutting Off Heater Shutting Off Burner Only pilot stays litInspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternTrouble Shooting ODS/PILOT and BurnerCabinet Cleaning and Mainte TroubleIng and Maintenance TROUBLE- ShootingIf you smell gas Shut off gas supplyDo not try to light any appliance BuildingTechnical Service Service Hints Service Publications20,000 Btu/Hr Models Parts Under Warranty Parts CentralsCGN20T CGN20TL CGN30T CGN30TL Parts List Description QTYAccessories Valve GA5010103873 Warranty Information Keep this Warranty