Desa FLAME-MAX Vintage, FLAME-MAX Golden installation manual Flame Adjustment Knob

Page 21

OPERATING HEATER (REMOTE-READY MODELS)

For Your Safety Read Before Lighting (Cont.) Lighting Instructions

21

OPERATING HEATER

Continued

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fire- place will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, starting in column 2, page 20.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in the OFF position.

WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clockwise to the OFF position (see Figure 34).

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, starting in column 2, page 19. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 34).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 22.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob counterclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON posi- tion to light burners. Note: AUTO is only functional when using GWMT1 or GWMS2 optional accessories.

11.Set flame adjustment knob to any level between HI and LO.

 

Flame Adjustment Knob

Control Knob

 

 

 

IH

 

 

 

AUTO

 

O

 

OFF

 

 

 

F

 

ON

N

F

 

O

P

 

LO

 

LI

 

 

TO

Ignitor Button

Selector Switch in OFF Position

 

 

Figure 34 - Control Knob and Ignitor Button Location (Shown as Supplied, No Control Options)

For morevisit www..com

110399-01A

Image 21
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsSafety Information Product Identification Optional Remote Control AccessoriesLocal Codes UnpackingAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors See options 1 and 2, . You can also remove door intoCheck GAS Type InstallationLOG Sizing Requirements Measured at 14 depthMinimum Noncombustible Material Clearances If Not Using MantelMantel Clearances Floor ClearancesDetermining Minimum Mantel Clearance Installing Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various StandardOnly. Follow all directions provided with accessory Trol accessories, do so at this time Remote-Ready ModelsDrill holes at marked locations using 3/16 drill bit Attach base assembly to fireplace floor using two masonryExternal Regulator With Vent Pointing Down Connecting to GAS SupplyPressure Testing gas Supply Piping system Checking GAS ConnectionsClose equipment shutoff valve see , Installing Logs Pressure Testing Heater Gas ConnectionsVintage Oak Two-Piece Log Set Golden Oak One-Piece Log Set Installing Vintage Oak Two-Piece Log SetGolden Oak Five-Piece Log Set Installing Golden Oak 5-Piece Log Set LogLighting Instructions Operating HeaterTo Turn OFF GAS to Appliance Manual Lighting ProcedureThermostat Control Operation Shutting Off HeaterVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingFlame Adjustment Knob Thermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrcta Series OperationPilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs We also recommend that you keep the burner tube and pilotTroubleshooting Clean burner see Cleaning and Mainte Gas odor even when control knob is in OFF ODS/pilot is partially clogged Clean ODS/pilot see CleaningLow line pressure CompanyOptional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceThermostat-Controlled Models Only Golden Oak Golden Oak 24 Remote-Ready 36 Remote-Ready SpecificationsService Hints Wiring DiagramTechnical Service Replacement PartsAccessories ODS Pilot Natural Gas ODS Pilot Propane/LP Illustrated Parts BreakdownVariable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG Models Parts ListVariable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Parts Available not Shown QTY From drawing.4 Natural GasParts Available not Shown THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Auxiliary Thermostat Mounting Clip REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models Parts List VYD36PNA and HD36NR Parts List For . .com Owners Registration Form Postage Required 110399-01A Warranty Information

FLAME-MAX Vintage, FLAME-MAX Golden specifications

Desa FLAME-MAX Golden and FLAME-MAX Vintage are two impressive heating solutions designed to elevate the comfort of any living space while enhancing its aesthetic appeal. Both products showcase advanced technologies and features that cater to consumers looking for efficiency, style, and reliability.

The FLAME-MAX Golden model is known for its state-of-the-art combustion technology. This innovative system maximizes heat output while minimizing fuel consumption, making it an eco-friendly choice. The unit operates with an adjustable flame feature, allowing users to control the intensity of the fire, thus optimizing the warmth according to personal preference. The sleek design of the Golden model incorporates a contemporary look with a polished finish, making it a stunning centerpiece in modern homes.

On the other hand, the FLAME-MAX Vintage model exudes a classic charm reminiscent of traditional wood-burning stoves. This model is perfect for those who appreciate a rustic aesthetic without compromising on modern efficiency. Its robust construction and timeless design appeal to homeowners aiming to add character to their spaces. The Vintage model also features advanced insulation technology, ensuring that heat remains contained and energy efficient.

Both models boast user-friendly interfaces, making operation seamless for consumers of all experience levels. They are equipped with remote control capabilities, allowing users to adjust the settings from across the room, enhancing convenience. Additionally, the programmable timer function ensures that heating can be scheduled according to daily routines, further supporting energy conservation.

Safety is also a top priority for Desa, with each model incorporating multiple safety features, such as automatic shut-off mechanisms and overheating protection. This focus on user safety provides peace of mind while enjoying the warmth and ambiance created by these exceptional heating solutions.

In summary, the Desa FLAME-MAX Golden and Vintage models combine elegance with functionality. Their main features, including adjustable flames, advanced combustion technology, user-friendly controls, and safety mechanisms, ensure an optimal heating experience without sacrificing style. Whether one prefers a modern look or a vintage appeal, both models stand out as top choices for efficient home heating solutions.