Desa FLAME-MAX Vintage Inspecting Burners, Pilot Flame Pattern, Burner Primary AIR Holes

Page 23

OPERATING HEATER (REMOTE-READY MODELS)

Optional Remote Operation (Cont.)

INSPECTING BURNERS

Pilot Flame Pattern

Burner Primary Air Holes

Main Burner

23

OPERATING HEATER

Continued

IMPORTANT: This remote control has been specially engi- neered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the tem- perature setting being turned up or down.

IMPORTANT: The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand- held remote control unit will heat up too quickly and turn the heater off.

3.To turn the burner off, press the AUTO/ON/OFF button un- til OFF lights. The pilot will remain lit.

IMPORTANT: To turn the pilot off, manually turn the con- trol knob on the heater to the OFF position.

 

Control Knob in

Flame Adjustment Knob

On Position

IH

 

F

PIL

ON

 

O

O

F

T

 

 

OFF

 

O

 

 

 

 

N

REMOTE

 

 

 

 

 

LO

 

 

 

Selector Switch in Remote Position

(Optional Remote Control)

Figure 37 - Setting the Selector switch, Control Knob, and Flame Adjustment Knob for Remote Operation

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 39 shows a correct pilot flame pattern. Figure 40 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 40

turn heater off (see To Turn Off Gas to Appliance, page 19 [Ther- mostat-Controlled Models], page 20 [Manually-Controlled Models], or page 22 [Remote-Ready Models])

see Troubleshooting, pages 25 through 27

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Pilot Burner

Pilot Burner

 

Thermocouple

Thermocouple

Figure 39 - Correct Pilot Flame

Figure 40 - Incorrect Pilot

Pattern (Your pilot may vary

Flame Pattern (Your pilot may

from pilots shown)

vary from pilots shown)

Shows

Temperature

Setting

The Log Heater will Automatically

Cycle between Pilot and the Heat Setting that has

been Selected

Increases Room

Temperature in

AUTO Mode

Decreases Room

Temperature in

AUTO Mode

Turns Burners

On or Off and

Allows You to

Choose the Auto

Setting

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the burner entrance. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

Figure 38 - Thermostat Hand-Held Remote Control Unit

Selections (GHRCTA Only)

For morevisit www..com

110399-01A

Image 23
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsSafety Information Unpacking Optional Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationSee options 1 and 2, . You can also remove door into Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsMeasured at 14 depth InstallationCheck GAS Type LOG Sizing RequirementsMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Mantel ClearancesFloor Clearances Area of Various Standard Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttach base assembly to fireplace floor using two masonry Trol accessories, do so at this time Remote-Ready ModelsOnly. Follow all directions provided with accessory Drill holes at marked locations using 3/16 drill bitExternal Regulator With Vent Pointing Down Connecting to GAS SupplyClose equipment shutoff valve see , Pressure Testing gas Supply Piping systemChecking GAS Connections Vintage Oak Two-Piece Log Set Installing LogsPressure Testing Heater Gas Connections Golden Oak One-Piece Log Set Installing Vintage Oak Two-Piece Log SetGolden Oak Five-Piece Log Set Installing Golden Oak 5-Piece Log Set LogLighting Instructions Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Thermostat Control OperationVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingFlame Adjustment Knob Ghrcta Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationMain Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesWe also recommend that you keep the burner tube and pilot Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsTroubleshooting Clean burner see Cleaning and Mainte Company ODS/pilot is partially clogged Clean ODS/pilot see CleaningGas odor even when control knob is in OFF Low line pressureThermostat-Controlled Models Only Optional Positioning of Thermostat Sensing BulbFor Masonry and FACTORY-BUILT Metal Fireplace Golden Oak Golden Oak 24 Remote-Ready 36 Remote-Ready SpecificationsReplacement Parts Wiring DiagramService Hints Technical ServiceAccessories ODS Pilot Natural Gas ODS Pilot Propane/LP Illustrated Parts BreakdownVariable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG Models Parts ListVariable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Parts Available not Shown QTY From drawing.4 Natural GasParts Available not Shown THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Auxiliary Thermostat Mounting Clip REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models Parts List VYD36PNA and HD36NR Parts List For . .com Owners Registration Form Postage Required 110399-01A Warranty Information

FLAME-MAX Vintage, FLAME-MAX Golden specifications

Desa FLAME-MAX Golden and FLAME-MAX Vintage are two impressive heating solutions designed to elevate the comfort of any living space while enhancing its aesthetic appeal. Both products showcase advanced technologies and features that cater to consumers looking for efficiency, style, and reliability.

The FLAME-MAX Golden model is known for its state-of-the-art combustion technology. This innovative system maximizes heat output while minimizing fuel consumption, making it an eco-friendly choice. The unit operates with an adjustable flame feature, allowing users to control the intensity of the fire, thus optimizing the warmth according to personal preference. The sleek design of the Golden model incorporates a contemporary look with a polished finish, making it a stunning centerpiece in modern homes.

On the other hand, the FLAME-MAX Vintage model exudes a classic charm reminiscent of traditional wood-burning stoves. This model is perfect for those who appreciate a rustic aesthetic without compromising on modern efficiency. Its robust construction and timeless design appeal to homeowners aiming to add character to their spaces. The Vintage model also features advanced insulation technology, ensuring that heat remains contained and energy efficient.

Both models boast user-friendly interfaces, making operation seamless for consumers of all experience levels. They are equipped with remote control capabilities, allowing users to adjust the settings from across the room, enhancing convenience. Additionally, the programmable timer function ensures that heating can be scheduled according to daily routines, further supporting energy conservation.

Safety is also a top priority for Desa, with each model incorporating multiple safety features, such as automatic shut-off mechanisms and overheating protection. This focus on user safety provides peace of mind while enjoying the warmth and ambiance created by these exceptional heating solutions.

In summary, the Desa FLAME-MAX Golden and Vintage models combine elegance with functionality. Their main features, including adjustable flames, advanced combustion technology, user-friendly controls, and safety mechanisms, ensure an optimal heating experience without sacrificing style. Whether one prefers a modern look or a vintage appeal, both models stand out as top choices for efficient home heating solutions.