Desa FLAME-MAX Golden Installation, Check GAS Type, LOG Sizing Requirements, Measured at 14 depth

Page 8

8

INSTALLATION

Check Gas Type

Installation and Clearances for Vent-Free Operation

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must in- stall heater. Follow all local codes.

NOTICE: State or local codes may only allow opera- tion of this appliance in a vented configuration. Check your state or local codes.

WARNING: Make sure the selector switch is in the OFF position before installing heater (Remote-Ready Models Only).

WARNING: Before installing in a solid fuel burn- ing fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue and firebox may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue damper before operating heater.

WARNING: Seal any fresh air vents or ash clean- out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom unless installed as a vented appliance, see page 11 (Remote-Ready and Variable Manually-Controlled Models Only)

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install log set. Call dealer where you bought log set for proper type fireplace.

INSTALLATION AND CLEARANCES FOR VENT-FREE OPERATION

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceil- ing, and adjoining wall.

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

 

 

 

18", 24",

16"

42"

30", and 36"

 

 

 

 

 

LOG SIZING REQUIREMENTS

Log

Minimum Firebox

 

Size

Height

Depth

Front

 

Rear *

 

 

 

Width

 

Width

18"

17"

14"

24"

 

20"

24"

17"

14"

28"

 

21"

30"

17"

14"

34"

 

24"

36"

17"

14"

40"

 

30"

 

 

 

 

 

 

* Measured at 14" depth.

For..com

110399-01A

Image 8
Contents Unvented VENT-FREE GAS LOG Heater What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Optional Remote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors See options 1 and 2, . You can also remove door intoInstallation Check GAS TypeLOG Sizing Requirements Measured at 14 depthIf Not Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance Mantel ClearancesFloor Clearances Installing Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various StandardTrol accessories, do so at this time Remote-Ready Models Only. Follow all directions provided with accessoryDrill holes at marked locations using 3/16 drill bit Attach base assembly to fireplace floor using two masonryConnecting to GAS Supply External Regulator With Vent Pointing DownClose equipment shutoff valve see , Pressure Testing gas Supply Piping systemChecking GAS Connections Vintage Oak Two-Piece Log Set Installing LogsPressure Testing Heater Gas Connections Installing Vintage Oak Two-Piece Log Set Golden Oak One-Piece Log SetInstalling Golden Oak 5-Piece Log Set Log Golden Oak Five-Piece Log SetOperating Heater Lighting InstructionsManual Lighting Procedure To Turn OFF GAS to ApplianceThermostat Control Operation Shutting Off HeaterREMOTE-READY Models For Your Safety Read Before Lighting Variable Control OperationFlame Adjustment Knob Optional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrcta Series OperationInspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs We also recommend that you keep the burner tube and pilotTroubleshooting Clean burner see Cleaning and Mainte ODS/pilot is partially clogged Clean ODS/pilot see Cleaning Gas odor even when control knob is in OFFLow line pressure CompanyThermostat-Controlled Models Only Optional Positioning of Thermostat Sensing BulbFor Masonry and FACTORY-BUILT Metal Fireplace Specifications Golden Oak Golden Oak 24 Remote-Ready 36 Remote-ReadyWiring Diagram Service HintsTechnical Service Replacement PartsAccessories Illustrated Parts Breakdown ODS Pilot Natural Gas ODS Pilot Propane/LPParts List Variable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG ModelsVariable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Parts Available not Shown QTY Natural Gas From drawing.4Parts Available not Shown THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Auxiliary Thermostat Mounting Clip REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models Parts List VYD36PNA and HD36NR Parts List For . .com Owners Registration Form Postage Required 110399-01A Warranty Information

FLAME-MAX Vintage, FLAME-MAX Golden specifications

Desa FLAME-MAX Golden and FLAME-MAX Vintage are two impressive heating solutions designed to elevate the comfort of any living space while enhancing its aesthetic appeal. Both products showcase advanced technologies and features that cater to consumers looking for efficiency, style, and reliability.

The FLAME-MAX Golden model is known for its state-of-the-art combustion technology. This innovative system maximizes heat output while minimizing fuel consumption, making it an eco-friendly choice. The unit operates with an adjustable flame feature, allowing users to control the intensity of the fire, thus optimizing the warmth according to personal preference. The sleek design of the Golden model incorporates a contemporary look with a polished finish, making it a stunning centerpiece in modern homes.

On the other hand, the FLAME-MAX Vintage model exudes a classic charm reminiscent of traditional wood-burning stoves. This model is perfect for those who appreciate a rustic aesthetic without compromising on modern efficiency. Its robust construction and timeless design appeal to homeowners aiming to add character to their spaces. The Vintage model also features advanced insulation technology, ensuring that heat remains contained and energy efficient.

Both models boast user-friendly interfaces, making operation seamless for consumers of all experience levels. They are equipped with remote control capabilities, allowing users to adjust the settings from across the room, enhancing convenience. Additionally, the programmable timer function ensures that heating can be scheduled according to daily routines, further supporting energy conservation.

Safety is also a top priority for Desa, with each model incorporating multiple safety features, such as automatic shut-off mechanisms and overheating protection. This focus on user safety provides peace of mind while enjoying the warmth and ambiance created by these exceptional heating solutions.

In summary, the Desa FLAME-MAX Golden and Vintage models combine elegance with functionality. Their main features, including adjustable flames, advanced combustion technology, user-friendly controls, and safety mechanisms, ensure an optimal heating experience without sacrificing style. Whether one prefers a modern look or a vintage appeal, both models stand out as top choices for efficient home heating solutions.