D20H, D30H AND D44H MODELS PORTABLE FORCED AIR HEATERS
STORING,
TRANSPORTING, OR SHIPPING
Note: If shipping, transport companies re- quire fuel tanks to be empty.
1.Drain fuel tank.
Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed.
2.Replace drain plug if provided.
3.If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters dur- ing future use.
4.Replace fuel cap or drain plug. Prop- erly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil.
5.If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.
IMPORTANT: Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.
PREVENTATIVE | WARNING: Never service heater | |
MAINTENANCE | ||
while it is plugged in, operating, or hot. | ||
SCHEDULE | Severe burns and electrical shock can | |
occur. | ||
|
|
Item | How Often | How To |
Fuel tank | Flush every | See Storing, Transporting, or Ship- |
| operation or as needed. | ping. |
Air output and | Replace every 500 hours of | See Air Output, Air Intake, and Lint |
lint filters | operation or once a year. | Filters, page 10. |
Air intake filter | Wash and dry with soap and | See Air Output, Air Intake, and Lint |
| water every 500 hours of op- | Filters, page 10. |
| eration or as needed. |
|
Fuel filter | Clean twice a heating season | See Fuel Filter, page 8. |
| or as needed. |
|
Ignitor | No maintenance required |
|
Fan blades | Clean every season or as | See Fan, page 13. |
| needed. |
|
Motor | Not required/permanently lu- |
|
| bricated |
|
6 | 105843 |