Desa installation manual Technical Service, Service Hints, Replacement Parts

Page 20

20

CLEANING AND MAINTENANCE TECHNICAL SERVICE SERVICE HINTS REPLACEMENT PARTS

CLEANING AND

MAINTENANCE

Continued

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 32). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Ports/Slots Burner Tube

Pilot Assembly

Pilot Air

Inlet Hole

Figure 32 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 13 through 15, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the 8 holes in the brass fitting at the entrance to the burner. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean as necessary. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage, blocked burner flame holes will create soot.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical service web site at www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your heater

the replacement part number

For..com

107068-01F

Image 20
Contents OWNER’S Operation and Installation Manual CLD3924PTA, CLD3924NTAWhat to do if YOU Smell GAS Winchester Oak Model ShownTable of Contents Safety InformationProduct Identification Product Features Local CodesUnpacking AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined Space and Unconfined Space Installation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Firebox Size Check GAS TypeMinimum Fireplace Clearance to Combustible Materials If Not Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance when Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Equipment Shutoff ValveInstalling Front Log Operating Heater What to do if YOU Smell GASLighting Instructions Variable Control OperationManual Lighting Procedure To Turn OFF GAS To ApplianceShutting Off Heater Shutting Off Burners Only pilot stays litThermostat Control Operation Cleaning Maintenance Inspecting BurnersReplacement Parts Technical ServiceService Hints Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceSpecifications Model CGS2718P CLD3018PA CLD3018PT CGS3124P CLD3924PTAIllustrated Parts Breakdown Parts List Variable Manually-Controlled Winchester Oak ModelsCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA CLD3018PTParts List Accessories Parts CentralOwners Registration Form Postage Required 107068-01F Warranty Information

CGS2718P, CGS2718N, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA, CLD3018PT, CLD3018NA specifications

Desa has made a significant impact in the home heating market with its range of innovative products. Among these, the models CGS2718P, CGS2718N, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA, CLD3018PT, and CLD3018NA stand out for their advanced features, technologies, and user-friendly characteristics.

The CGS2718P and CGS2718N are known for their compact design and energy-efficient performance, making them ideal for various settings from residential spaces to smaller commercial applications. These models typically offer a high heating capacity with minimal energy consumption. Their easy-to-use controls allow for precise temperature adjustments, ensuring optimal comfort. Both versions are equipped with safety features to prevent overheating and unwanted gas leaks, highlighting Desa’s commitment to user safety.

On the other hand, the CGS3124P and CGS3124N models elevate performance with larger heating capabilities. These models incorporate modern technology that maximizes heat output while minimizing emissions, aligning with environmentally friendly practices. Their sleek designs blend well with different interior styles, while being robust enough for prolonged use. They often come with remote control features, enhancing user convenience.

Moving on to the CLD series, the CLD3018PA and CLD3018NA are designed to cater to users seeking versatility and performance. These models feature dual fuel capability, allowing for either propane or natural gas usage, providing flexibility depending on availability. Their advanced ignition systems ensure quick and reliable starting, while the stylish appearance complements any décor, making them a popular choice for homeowners.

The CLD3924PTA and CLD3924NTA extend the line with enhanced heating capabilities, giving users even more options for whole-home heating or larger spaces. These units are structured for efficient fuel utilization and come equipped with cutting-edge thermostat technology for accurate temperature regulation.

Finally, the CLD3018PT and CLD3018NA models serve as adaptable solutions that cater to various heating needs. Featuring modern aesthetics and user-friendly installations, these units provide reliable warmth and comfort.

Overall, the Desa series combines thoughtful engineering with aesthetic design, making them an appealing choice for anyone looking to enhance their home's warmth while maintaining efficiency and safety.