Desa Check GAS Type, Minimum Fireplace Clearance to Combustible Materials, Minimum Firebox Size

Page 7

INSTALLATION

Check Gas Type Installation and Clearances

7

INSTALLATION

Continued

WARNING: Seal any fresh air vents or ash clean- out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom unless installed as a vented appliance (Variable Manually-Controlled Models Only) (see page 10)

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use only the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION AND CLEARANCES (Vent-Free Operation Only)

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceil- ing, and adjoining wall.

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

 

 

 

18", 24"

16"

42"

LOG SIZING REQUIREMENTS

 

 

Minimum Firebox Size

Log

 

 

 

Front

Rear

Size

Height

Depth

Width

Width*

 

 

 

 

 

 

18"

 

17"

14"

24"

20"

24"

 

17"

14"

28"

21"

 

 

 

 

 

 

*Measured at 14" Depth

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or certified vent-free firebox.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 8.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace cabinet (see Figure 4).

Note: When installing your gas logs into a manufactured fire- box, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

 

 

 

 

 

 

 

 

 

 

121/4

 

 

 

 

 

 

 

 

 

 

 

101/2

 

 

Example

 

 

 

 

 

 

8 3/4

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

INCHES

 

 

 

 

 

 

 

 

 

 

51/4

 

 

 

 

 

 

 

 

 

 

31/2

 

 

 

 

 

 

 

 

 

 

13/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8

 

 

 

 

 

 

 

 

 

 

 

7/16

 

FIREBOX

.5

1

2

4

6

8

10

12

14

16 *

 

 

 

 

 

INCHES

 

 

 

 

 

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for Combustible to Wall

For morevisit www..com

107068-01F

Image 7
Contents Winchester Oak Model Shown OWNER’S Operation and Installation ManualCLD3924PTA, CLD3924NTA What to do if YOU Smell GASSafety Information Table of ContentsProduct Identification AIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined Space and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors InstallationVentilation AIR Ventilation Air From Inside BuildingMinimum Fireplace Clearance to Combustible Materials Check GAS TypeMinimum Firebox Size Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance when Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemEquipment Shutoff Valve Pressure Testing Heater Gas ConnectionsInstalling Front Log What to do if YOU Smell GAS Operating HeaterVariable Control Operation Lighting InstructionsShutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterThermostat Control Operation Inspecting Burners Cleaning MaintenanceService Hints Technical ServiceReplacement Parts Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbModel CGS2718P CLD3018PA CLD3018PT CGS3124P CLD3924PTA SpecificationsIllustrated Parts Breakdown Variable Manually-Controlled Winchester Oak Models Parts ListCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3018PT CLD3924NTA CLD3924PTAParts List Parts Central AccessoriesOwners Registration Form Postage Required 107068-01F Warranty Information

CGS2718P, CGS2718N, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA, CLD3018PT, CLD3018NA specifications

Desa has made a significant impact in the home heating market with its range of innovative products. Among these, the models CGS2718P, CGS2718N, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA, CLD3018PT, and CLD3018NA stand out for their advanced features, technologies, and user-friendly characteristics.

The CGS2718P and CGS2718N are known for their compact design and energy-efficient performance, making them ideal for various settings from residential spaces to smaller commercial applications. These models typically offer a high heating capacity with minimal energy consumption. Their easy-to-use controls allow for precise temperature adjustments, ensuring optimal comfort. Both versions are equipped with safety features to prevent overheating and unwanted gas leaks, highlighting Desa’s commitment to user safety.

On the other hand, the CGS3124P and CGS3124N models elevate performance with larger heating capabilities. These models incorporate modern technology that maximizes heat output while minimizing emissions, aligning with environmentally friendly practices. Their sleek designs blend well with different interior styles, while being robust enough for prolonged use. They often come with remote control features, enhancing user convenience.

Moving on to the CLD series, the CLD3018PA and CLD3018NA are designed to cater to users seeking versatility and performance. These models feature dual fuel capability, allowing for either propane or natural gas usage, providing flexibility depending on availability. Their advanced ignition systems ensure quick and reliable starting, while the stylish appearance complements any décor, making them a popular choice for homeowners.

The CLD3924PTA and CLD3924NTA extend the line with enhanced heating capabilities, giving users even more options for whole-home heating or larger spaces. These units are structured for efficient fuel utilization and come equipped with cutting-edge thermostat technology for accurate temperature regulation.

Finally, the CLD3018PT and CLD3018NA models serve as adaptable solutions that cater to various heating needs. Featuring modern aesthetics and user-friendly installations, these units provide reliable warmth and comfort.

Overall, the Desa series combines thoughtful engineering with aesthetic design, making them an appealing choice for anyone looking to enhance their home's warmth while maintaining efficiency and safety.