OPERATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR YOUR SAFETY READ BEFORE LIGHTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you do not follow these instructions exactly, a fire or

 

 

 

 

 

 

 

 

 

 

explosion may result causing property damage, personal

 

 

 

 

 

 

 

injury or loss of life.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. This appliance has a pilot which must be lighted by hand. When lighting

 

 

 

 

the pilot, follow these instructions exactly.

 

 

 

 

 

 

 

 

 

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure

 

 

 

 

to smell next to the floor because some gas is heavier than air and will

 

 

 

 

settle on the floor.

 

 

 

 

 

 

 

 

 

 

 

 

 

WHAT TO DO IF YOU SMELL GAS

 

 

 

 

 

 

 

 

 

 

 

• Do not try to light any appliance.

 

 

 

 

 

 

 

 

 

 

 

• Do not touch any electric switch; do not use any phone in your build-

 

 

 

 

 

ing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Immediately call your gas supplier from a neighbor’s phone. Follow

 

 

 

 

 

the gas supplier’s instructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• If you cannot reach your gas supplier, call the fire department.

 

 

 

C. Use only your hand to push in or turn the gas control knob. Never use

 

 

 

 

tools. If the knob will not push in or turn by hand, don’t try to repair it,

 

 

 

 

call a qualified service technician or gas supplier. Force or attempted

 

 

 

 

repair may result in a fire or explosion.

 

 

 

 

 

 

 

 

 

D. Do not use this appliance if any part has been under water. Immediately

 

 

 

 

call a qualified service technician to inspect the appliance and to replace

 

 

 

 

any part of the control system and any gas control which has been under

 

 

 

 

water.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIGHTING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. STOP! Read the safety information above.

 

 

 

 

 

 

 

 

2. Make sure manual shutoff valve is fully open.

 

 

 

 

 

 

 

 

3. Turn control knob clockwise

to the OFF position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control Knob

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PILOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IGN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MED

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 16 - Control Knob In The OFF Position

 

 

 

 

 

 

 

 

Continued 17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

101827

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Information Product Safety DeviceLocal Codes UnpackingProviding Adequate Ventilation AIR forVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRInstallation Items Installing To WallCheck GAS Type Locating HeaterInstalling to Wall Mounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsSupply Connecting To GASQualified service person must connect heater to gas supply Checking GAS Checking Pressure Testing Heater GAS ConnectionsGAS ConnectionsHeater OperatingPilot Operating HeaterTo Select Heating Level Pilot Flame Pattern Operating Heater Inspecting BurnerShutting Off Heater Shutting Off Burner Only pilot stays litGRH/OV 019A Maintenance CleaningTrouble Shooting ODS/PILOT and Burner OrificeTrouble Cleaning and MainteTROUBLE- Shooting Technical ServiceIng statement at TopParts Under Warranty Replacement PartsParts Not Under Warranty HintsCentrals AccessoriesPublications FAN Kits GA3100, GA3100A, and GA3200TAModel CGP16RA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListModel CGP26D Parts List Keep this Warranty Warranty Information

CGP26D, CGP16RA specifications

Desa CGP26D and CGP16RA are powerful and efficient products in the world of portable heating and cooling solutions, catering to various consumer needs. Known for their reliability and user-friendly features, these models have established a solid reputation among users looking for competent climate control.

The CGP26D model stands out for its energy efficiency and advanced heating capabilities. It is designed with a high-performance combustion chamber that maximizes heat output while minimizing fuel consumption. This model utilizes a state-of-the-art thermostat, providing users with precise temperature control to ensure optimal comfort. The CGP26D's compact design makes it an ideal choice for both residential and commercial spaces, allowing users to effectively heat areas without taking up much room. Its portability is further enhanced by the integrated handle and lightweight construction, making it easy to move from one location to another.

In terms of safety features, the CGP26D is equipped with a robust safety shut-off mechanism that activates in case of overheating or accidental tipping, providing peace of mind for users. With a range of heat settings, users can customize the output to suit their specific needs, making it a versatile option for various applications.

On the other hand, the CGP16RA model offers similar benefits but is more focused on cooling solutions. This model incorporates advanced refrigerant technology that facilitates rapid cooling, making it suitable for use in hotter climates. Its energy-efficient compressor operates quietly, ensuring that users can enjoy a cool environment without disruptive noise. The CGP16RA also features multiple cooling modes, allowing users to select the most comfortable setting for their preferences.

Both models come with user-friendly control panels, enabling effortless adjustments and quick access to settings. Energy efficiency is a hallmark of both the CGP26D and CGP16RA, as they are designed to reduce environmental impact while maximizing user comfort. With a blend of modern technology and practical design, these models are perfect for anyone looking to manage indoor climates effectively and sustainably.

In summary, the Desa CGP26D and CGP16RA are impressive products that provide robust heating and cooling solutions, respectively. Their advanced features, energy efficiency, and safety mechanisms make them desirable choices for consumers seeking reliability and convenience in climate control technology. Whether you need to warm up a chilly room or cool down in the summer heat, these Desa models offer the performance and versatility to meet your needs.