Desa CGP26D, CGP16RA installation manual Trouble, Cleaning and Mainte

Page 23

TROUBLE-

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

SHOOTING

 

 

 

 

 

 

When control knob is

1. Gas supply turned off

1.

Turn on gas supply or

Continued

 

pressed in and turned

 

or manual shutoff

 

open manual shutoff

 

to the PILOT/IGN

 

valve closed

 

valve

 

position, there is

2.

Control knob not

2.

Press in control knob

 

spark at ODS/pilot

 

pressed in while being

 

while turning to

 

but no ignition

 

turned to PILOT/IGN

 

PILOT/IGN position

 

 

 

position

 

 

 

 

 

3.

Air in gas lines when

3.

Continue holding down

 

 

 

installed

 

control knob. Repeat

 

 

 

 

 

igniting operation until

 

 

 

 

 

air is removed

 

 

4.

Depleted gas supply

4.

Contact local propane/

 

 

 

 

 

LP gas company.

 

 

5.

ODS/pilot is clogged

5.

Clean ODS/pilot (see

 

 

 

 

 

Cleaning and Mainte-

 

 

 

 

 

nance, page 22) or

 

 

 

 

 

replace ODS/pilot

 

 

 

 

 

assembly

 

 

6.

Gas regulator setting is

6.

Replace gas regulator

 

 

 

not correct

 

 

 

 

 

 

 

 

 

 

 

ODS/pilot lights but

1.

Control knob not fully

1.

Press in control knob

 

flame goes out when

 

pressed in

 

fully

 

control knob is

2.

Control knob not

2.

After ODS/pilot lights,

 

released

 

pressed in long enough

 

keep control knob

 

 

 

 

 

pressed in 10 seconds

 

 

3.

Manual shutoff valve

3.

Fully open manual

 

 

 

not fully open

 

shut-off valve

 

 

4.

Thermocouple connec-

4.

Hand tighten until

 

 

 

tion loose at control

 

snug, then tighten 1/4

 

 

 

valve

 

turn more

 

 

5.

Pilot flame not touch-

5.

A) Contact local

 

 

 

ing thermocouple,

 

propane/LP gas

 

 

 

which allows thermo-

 

company

 

 

 

couple to cool, causing

 

 

 

 

 

 

pilot flame to go out.

 

B) Clean ODS/pilot

 

 

 

This problem could be

 

(see Cleaning and

 

 

 

caused by one or both

 

Maintenance, page 22)

 

 

 

of the following:

 

or replace ODS/pilot

 

 

 

A) Low gas pressure

 

assembly

 

 

 

B) Dirty or partially

 

 

 

 

 

 

clogged ODS/pilot

 

 

 

 

 

6.

Thermocouple dam-

6.

Replace thermocouple

 

 

 

aged

 

 

 

 

 

7.

Control valve damaged

7.

Replace control valve

Continued

101827

23

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Information Unpacking Safety DeviceProduct Local CodesProviding Adequate Ventilation AIR forVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRLocating Heater Installing To WallInstallation Items Check GAS TypeInstalling to Wall Methods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsSupply Connecting To GASQualified service person must connect heater to gas supply Checking GAS Connections Pressure Testing Heater GAS ConnectionsChecking GASHeater OperatingPilot Operating HeaterTo Select Heating Level Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterGRH/OV 019A ODS/PILOT and Burner Orifice CleaningMaintenance Trouble ShootingTrouble Cleaning and MainteTROUBLE- Shooting Top ServiceTechnical Ing statement atHints Replacement PartsParts Under Warranty Parts Not Under WarrantyFAN Kits GA3100, GA3100A, and GA3200TA AccessoriesCentrals PublicationsModel CGP16RA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListModel CGP26D Parts List Keep this Warranty Warranty Information

CGP26D, CGP16RA specifications

Desa CGP26D and CGP16RA are powerful and efficient products in the world of portable heating and cooling solutions, catering to various consumer needs. Known for their reliability and user-friendly features, these models have established a solid reputation among users looking for competent climate control.

The CGP26D model stands out for its energy efficiency and advanced heating capabilities. It is designed with a high-performance combustion chamber that maximizes heat output while minimizing fuel consumption. This model utilizes a state-of-the-art thermostat, providing users with precise temperature control to ensure optimal comfort. The CGP26D's compact design makes it an ideal choice for both residential and commercial spaces, allowing users to effectively heat areas without taking up much room. Its portability is further enhanced by the integrated handle and lightweight construction, making it easy to move from one location to another.

In terms of safety features, the CGP26D is equipped with a robust safety shut-off mechanism that activates in case of overheating or accidental tipping, providing peace of mind for users. With a range of heat settings, users can customize the output to suit their specific needs, making it a versatile option for various applications.

On the other hand, the CGP16RA model offers similar benefits but is more focused on cooling solutions. This model incorporates advanced refrigerant technology that facilitates rapid cooling, making it suitable for use in hotter climates. Its energy-efficient compressor operates quietly, ensuring that users can enjoy a cool environment without disruptive noise. The CGP16RA also features multiple cooling modes, allowing users to select the most comfortable setting for their preferences.

Both models come with user-friendly control panels, enabling effortless adjustments and quick access to settings. Energy efficiency is a hallmark of both the CGP26D and CGP16RA, as they are designed to reduce environmental impact while maximizing user comfort. With a blend of modern technology and practical design, these models are perfect for anyone looking to manage indoor climates effectively and sustainably.

In summary, the Desa CGP26D and CGP16RA are impressive products that provide robust heating and cooling solutions, respectively. Their advanced features, energy efficiency, and safety mechanisms make them desirable choices for consumers seeking reliability and convenience in climate control technology. Whether you need to warm up a chilly room or cool down in the summer heat, these Desa models offer the performance and versatility to meet your needs.