Desa CGP26D, CGP16RA installation manual Safety Information

Page 3

SAFETY INFORMATION

Continued

WARNINGS Continued

WARNING: Any change to this heater or its controls can be dangerous.

1.Use only propane/LP gas. Do not convert heater to use different fuel type.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.This heater shall not be installed in a bedroom or bathroom.

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

5.Never install the heater

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

6.Always run heater with control knob at LOW, MEDIUM, or HIGH locked positions. Never set control knob between locked positions. Poor combustion may result.

7.This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 8.

8.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

9.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

10.Never place any objects on the heater.

11.Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

12.Carefully supervise young children when they are in same room with heater.

13.Make sure grill guard is in place before running heater.

14.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

15.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

16.Operating heater above elevations of 4,500 feet may cause pilot outage.

101827

3

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Information Unpacking Safety DeviceProduct Local CodesAIR for VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRLocating Heater Installing To WallInstallation Items Check GAS TypeInstalling to Wall Methods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting To GAS Qualified service person must connect heater to gas supplySupply Checking GAS Connections Pressure Testing Heater GAS ConnectionsChecking GASHeater OperatingPilot Operating HeaterTo Select Heating Level Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterGRH/OV 019A ODS/PILOT and Burner Orifice CleaningMaintenance Trouble ShootingTrouble Cleaning and MainteTROUBLE- Shooting Top ServiceTechnical Ing statement atHints Replacement PartsParts Under Warranty Parts Not Under WarrantyFAN Kits GA3100, GA3100A, and GA3200TA AccessoriesCentrals PublicationsModel CGP16RA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListModel CGP26D Parts List Keep this Warranty Warranty Information

CGP26D, CGP16RA specifications

Desa CGP26D and CGP16RA are powerful and efficient products in the world of portable heating and cooling solutions, catering to various consumer needs. Known for their reliability and user-friendly features, these models have established a solid reputation among users looking for competent climate control.

The CGP26D model stands out for its energy efficiency and advanced heating capabilities. It is designed with a high-performance combustion chamber that maximizes heat output while minimizing fuel consumption. This model utilizes a state-of-the-art thermostat, providing users with precise temperature control to ensure optimal comfort. The CGP26D's compact design makes it an ideal choice for both residential and commercial spaces, allowing users to effectively heat areas without taking up much room. Its portability is further enhanced by the integrated handle and lightweight construction, making it easy to move from one location to another.

In terms of safety features, the CGP26D is equipped with a robust safety shut-off mechanism that activates in case of overheating or accidental tipping, providing peace of mind for users. With a range of heat settings, users can customize the output to suit their specific needs, making it a versatile option for various applications.

On the other hand, the CGP16RA model offers similar benefits but is more focused on cooling solutions. This model incorporates advanced refrigerant technology that facilitates rapid cooling, making it suitable for use in hotter climates. Its energy-efficient compressor operates quietly, ensuring that users can enjoy a cool environment without disruptive noise. The CGP16RA also features multiple cooling modes, allowing users to select the most comfortable setting for their preferences.

Both models come with user-friendly control panels, enabling effortless adjustments and quick access to settings. Energy efficiency is a hallmark of both the CGP26D and CGP16RA, as they are designed to reduce environmental impact while maximizing user comfort. With a blend of modern technology and practical design, these models are perfect for anyone looking to manage indoor climates effectively and sustainably.

In summary, the Desa CGP26D and CGP16RA are impressive products that provide robust heating and cooling solutions, respectively. Their advanced features, energy efficiency, and safety mechanisms make them desirable choices for consumers seeking reliability and convenience in climate control technology. Whether you need to warm up a chilly room or cool down in the summer heat, these Desa models offer the performance and versatility to meet your needs.