Desa CGP16RA, CGP26D installation manual TROUBLE- Shooting

Page 24

24

TROUBLE- SHOOTING

Continued

 

OBSERVED

POSSIBLE

 

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

 

Burner(s) does not

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

 

light after ODS/pilot

 

clogged

 

(see Cleaning and

 

is lit

 

 

 

Maintenance, page 22)

 

 

 

 

 

or replace burner

 

 

 

 

 

orifice(s)

 

 

2.

Burner orifice(s)

2.

Replace burner orifice(s)

 

 

 

diameter is too small

 

 

 

 

 

3.

Inlet gas pressure is

3.

Contact local propane/

 

 

 

too low

 

LP gas company

 

 

 

 

 

 

 

 

Delayed ignition of

1.

Manifold pressure is

1.

Contact local propane/

 

burner(s)

 

too low

 

LP gas company

 

 

2.

Burner orifice(s) is

2.

Clean burner orifice(s)

 

 

 

clogged

 

(see Cleaning and

 

 

 

 

 

Maintenance, page 22)

 

 

 

 

 

or replace burner

 

 

 

 

 

orifice(s)

 

 

 

 

 

 

 

 

Burner backfiring

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

 

during combustion

 

clogged or damaged

 

(see Cleaning and

 

 

 

 

 

Maintenance, page 22)

 

 

 

 

 

or replace burner

 

 

 

 

 

orifice(s)

 

 

2.

Inlet gas pressure is

2.

Contact local propane/

 

 

 

too low

 

LP gas company

 

 

3.

Burner damaged

3.

Replace burner

 

 

4.

Gas regulator defective

4.

Replace gas regulator

 

 

 

 

 

 

 

Burner plaque(s) does

1. Plaque damaged

1.

Replace burner

 

not glow

2.

Inlet gas pressure is

2.

Contact local propane/

 

 

 

too low

 

LP gas company

 

 

3.

Control knob set

3.

Turn control knob until

 

 

 

between locked

 

it locks at desired setting

 

 

 

positions

 

 

 

 

 

 

 

 

 

 

Slight smoke or odor

1. Residues from manu-

1.

Problem will stop after a

 

during initial operation

 

facturing processes

 

few hours of operation

 

 

 

 

 

 

Heater produces a

1. Metal expanding while

1.

This is common with

 

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

 

just after burner is lit

 

while cooling

 

excessive, contact

 

or shut off

 

 

 

qualified service person

101827

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Information Safety Device ProductLocal Codes UnpackingAIR for VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation AIR Ventilation Air From OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterInstalling to Wall Installing Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS Qualified service person must connect heater to gas supplySupply Checking GAS Pressure Testing Heater GAS Connections CheckingGAS ConnectionsOperating HeaterOperating Heater PilotTo Select Heating Level Operating Heater Inspecting Burner Pilot Flame PatternShutting Off Heater Shutting Off Burner Only pilot stays litGRH/OV 019A Cleaning MaintenanceTrouble Shooting ODS/PILOT and Burner OrificeCleaning and Mainte TroubleTROUBLE- Shooting Service TechnicalIng statement at TopReplacement Parts Parts Under WarrantyParts Not Under Warranty HintsAccessories CentralsPublications FAN Kits GA3100, GA3100A, and GA3200TAIllustrated Parts Breakdown Model CGP16RAParts List KEY Part Number Description QTYModel CGP26D Parts List Warranty Information Keep this Warranty

CGP26D, CGP16RA specifications

Desa CGP26D and CGP16RA are powerful and efficient products in the world of portable heating and cooling solutions, catering to various consumer needs. Known for their reliability and user-friendly features, these models have established a solid reputation among users looking for competent climate control.

The CGP26D model stands out for its energy efficiency and advanced heating capabilities. It is designed with a high-performance combustion chamber that maximizes heat output while minimizing fuel consumption. This model utilizes a state-of-the-art thermostat, providing users with precise temperature control to ensure optimal comfort. The CGP26D's compact design makes it an ideal choice for both residential and commercial spaces, allowing users to effectively heat areas without taking up much room. Its portability is further enhanced by the integrated handle and lightweight construction, making it easy to move from one location to another.

In terms of safety features, the CGP26D is equipped with a robust safety shut-off mechanism that activates in case of overheating or accidental tipping, providing peace of mind for users. With a range of heat settings, users can customize the output to suit their specific needs, making it a versatile option for various applications.

On the other hand, the CGP16RA model offers similar benefits but is more focused on cooling solutions. This model incorporates advanced refrigerant technology that facilitates rapid cooling, making it suitable for use in hotter climates. Its energy-efficient compressor operates quietly, ensuring that users can enjoy a cool environment without disruptive noise. The CGP16RA also features multiple cooling modes, allowing users to select the most comfortable setting for their preferences.

Both models come with user-friendly control panels, enabling effortless adjustments and quick access to settings. Energy efficiency is a hallmark of both the CGP26D and CGP16RA, as they are designed to reduce environmental impact while maximizing user comfort. With a blend of modern technology and practical design, these models are perfect for anyone looking to manage indoor climates effectively and sustainably.

In summary, the Desa CGP26D and CGP16RA are impressive products that provide robust heating and cooling solutions, respectively. Their advanced features, energy efficiency, and safety mechanisms make them desirable choices for consumers seeking reliability and convenience in climate control technology. Whether you need to warm up a chilly room or cool down in the summer heat, these Desa models offer the performance and versatility to meet your needs.