OPERATING | 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including | ||
near the floor. If you smell gas, STOP! Follow “B” in the safety information | |||
HEATER | |||
at the top of page 12. If you don’t smell gas, go to the next step. | |||
Continued | 5. Press in control knob and turn counterclockwise | ||
| |||
| position. Keep control knob pressed in for five (5) seconds (see Figure 15, | ||
| page 16). |
| |
| Note: You may be running this heater for the first time after hooking up | ||
| to gas supply. If so, the control knob may need to be pressed in for 30 | ||
| seconds. This will allow air to bleed from the gas system. | ||
| • If control knob does not pop up when released, contact a qualified | ||
| service person or gas supplier for repairs. |
| |
| 6. With control knob pressed in, push down and release ignitor button. This | ||
| will light pilot. The pilot is attached to the front of burner. The pilot can be | ||
| seen through the glass panel. If needed, keep pressing ignitor button until | ||
| pilot lights. |
| |
| Note: If pilot does not stay lit, refer to Troubleshooting, pages 20 through | ||
| 23. Also contact a qualified service person or gas supplier for repairs. | ||
| Until repairs are made, light pilot with match. To light pilot with match, | ||
| see Manual Lighting Procedure, page 18. |
| |
| Ignitor Electrode | ||
| Thermocouple | Pilot Burner |
Figure 16 - Pilot
7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7.
8.Turn control knob counterclockwise
control knob and turn counterclockwise
Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
Continued | 17 |
|
103546