Desa CGN6L, CGN10L installation manual Observed Possible Remedy Problem Cause

Page 22

TROUBLE- SHOOTING

OBSERVED

POSSIBLE

REMEDY

PROBLEM

CAUSE

 

 

 

Continued

Burner does not light after ODS/pilot is lit

1.Burner orifice is clogged

2.Burner orifice diameter is too small

3.Inlet gas pressure is too low

1.Clean burner orifice (see Cleaning and Mainte- nance, page 20) or replace burner orifice

2.Replace burner orifice

3.Contact local natural gas company

Delayed ignition of

1.

Manifold pressure is

1.

Contact local natural gas

burner

 

too low

 

company

 

2.

Burner orifice is

2.

Clean burner orifice (see

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

nance, page 20) or

 

 

 

 

replace burner orifice

 

 

 

 

 

Burner backfiring

1.

Burner orifice is

1.

Clean burner orifice (see

during combustion

 

clogged or damaged

 

Cleaning and Mainte-

 

 

 

 

nance, page 20) or

 

 

 

 

replace burner orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

Yellow flame during burner combustion

1.Not enough air

2.Inlet gas pressure is too low

3.Gas regulator defective

1.Check burner for dirt and debris. If found, clean burner (see Cleaning and Mainte- nance, page 20)

2.Contact local natural gas company

3.Replace gas regulator

22

Slight smoke or odor

1.

Residues from manu-

1.

Problem will stop after a

during initial operation

 

facturing processes

 

few hours of operation

 

 

 

 

 

Heater produces a

1.

Turning control knob

1.

Turn control knob to

whistling noise when

 

to HIGH position

 

LOW position and let

burner is lit

 

when burner is cold

 

warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air

 

 

 

 

is removed from line.

 

 

 

 

Have gas checked by

 

 

 

 

local natural gas company

 

3.

Air passageways on

3.

Observe minimum

 

 

heater blocked

 

installation clearances

 

 

 

 

(see Figure 4, page 10)

 

4.

Dirty or partially

4.

Clean burner (see

 

 

clogged burner orifice

 

Cleaning and Mainte-

 

 

 

 

nance, page 20) or

 

 

 

 

replace burner orifice.

103546

Image 22
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information001 Product Identification Local Codes Unpacking Product FeaturesSafety Device Piezo Ignition SystemVentilation Fresh AIR ForCombustion Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Fresh AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsCheck GAS Type Installing to WallInstallation Items Locating HeaterInstalling Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorInstalling to Wall Connecting to GAS Supply To GAS Supply ConnectingPressure Testing GAS Supply Piping System Checking GASPressure Testing Heater GAS Connections CheckingFor Your Safety Read Before Lighting Operating HeaterHeater OperatingShutting Off Heater Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off Burner Only pilot stays litBurner Flame Pattern Model CGN6 will be lower due to lower input ratingTrouble Shooting CleaningMaintenance ODS/PILOT and Burner OrificeSee Cleaning TROUBLE- ShootingObserved Possible Remedy Problem Cause Do not try to light any appliance If you smell gasShut off gas supply Ing statement atHints ServiceTechnical PartsCentrals Service Publications AccessoryValve GA5010 CGN10L CGN6L Parts List KEY Part Number for Description QTY CGN6L CGN10LWarranty Information Keep this Warranty