CLEANING | WARNING | |
AND |
| |
Turn off heater and let cool before cleaning. | ||
MAINTENANCE |
|
|
| ||
|
|
CAUTION
You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNER ORIFICE
• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
CABINET
Air Passageways
•Use a vacuum cleaner or pressurized air to clean.
Exterior
•Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
TROUBLE- |
|
| WARNING |
|
|
SHOOTING |
| ||||
Turn off heater and let cool before servicing. Only a qualified | |||||
| service person should service and repair heater. | ||||
Note: All troubleshooting |
|
|
|
|
|
|
|
|
|
| |
items are listed in order of |
|
|
|
|
|
operation. |
|
| CAUTION |
|
|
|
|
|
|
| |
| Never use a wire, needle, or similar object to clean ODS/pilot. This | ||||
| can damage ODS/pilot unit. |
|
| ||
|
|
|
|
| |
| OBSERVED | POSSIBLE |
|
| |
| PROBLEM | CAUSE | REMEDY | ||
|
|
|
|
|
|
| When ignitor button is | 1. | Ignitor electrode posi- | 1. | Replace ignitor |
| pressed, there is no |
| tioned wrong |
|
|
| spark at ODS/pilot | 2. | Ignitor electrode broken | 2. | Replace ignitor |
|
| 3. | Ignitor electrode not con- | 3. | Reconnect ignitor cable |
|
|
| nected to ignitor cable |
|
|
|
| 4. | Ignitor cable pinched or | 4. | Free ignitor cable if |
|
|
| wet |
| pinched by any metal or |
|
|
|
|
| tubing. Keep ignitor |
|
|
|
|
| cable dry |
|
| 5. | Piezo ignitor nut is loose | 5. | Tighten nut holding pi- |
|
|
|
|
| ezo ignitor to heater |
|
|
|
|
| cabinet. Nut is located in- |
|
|
|
|
| side heater cabinet at top |
|
| 6. | Broken ignitor cable | 6. | Replace ignitor cable |
|
| 7. | Bad piezo ignitor | 7. | Replace piezo ignitor |
20
103546