Desa CGS2718N installation manual Local Codes Unpacking Product Features, Operation, Safety Pilot

Page 4

PRODUCT IDENTIFICATION

LOCAL CODES

UNPACKING

PRODUCT

FEATURES

4

Back Log

Crossover Log

Front Log

Burner

Piezo

Ignitor

Control Knob

Figure 1 - Vent-Free Gas Log Heater

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.

*Available from: American National Standards Institute, Inc. 1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

Operation

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters. You can operate heater as a vented product by opening flue damper.

Safety Pilot

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Piezo Ignition System

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

102988

Image 4
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Burner patterns can cause sooting Local Codes Unpacking Product Features Safety PilotOperation Piezo Ignition SystemVentilation AIR forProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Check GAS TypeLOG Sizing Requirements Minimum Fireplace ClearanceMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances Minimum clearances shown in when using hood Floor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededMounting Bracket Connecting to GAS Supply Checking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling For Your Safety Read Before Lighting Operating HeaterHeater OperatingInspecting Burners Pilot Flame PatternCleaning MaintenanceTrouble Shooting ODS/PILOT and BurnerMaintenance, TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Service Hints Technical ServiceModel Parts Not Under Warranty Parts Under WarrantyParts Central Accessories Valve GA5010Hood GA6050 Hood GA6052Illustrated Parts Breakdown Parts List CGS2718N CGS3124NWarranty Information Keep this Warranty

CGS2718N specifications

Desa CGS2718N is an innovative gas stove designed to enhance cooking efficiency and convenience in modern kitchens. This versatile appliance combines advanced technology with thoughtful design, catering to the needs of both amateur cooks and professional chefs.

One of the standout features of the CGS2718N is its powerful burners. Equipped with multiple high-efficiency burners, it ensures even heat distribution for optimal cooking results. The stove supports high-temperature cooking which is essential for tasks such as searing meats or achieving a perfect stir-fry. The burners also feature adjustable flame control, allowing users to customize heat levels with precision.

In terms of design, the CGS2718N boasts a sleek and modern aesthetic that fits seamlessly into various kitchen styles. The stainless steel surface is easy to clean and resistant to stains, ensuring that the stove maintains its elegant appearance over time. Its compact size makes it ideal for kitchens with limited space, while still providing ample cooking area.

Another notable characteristic of the CGS2718N is its safety features, which include flame failure devices that automatically shut off the gas supply if a flame is extinguished. This ensures peace of mind for families, especially in households with children or pets. Moreover, the stove is equipped with an ignition system that provides a reliable spark for easy, quick lighting without the need for matches.

The CGS2718N also includes a convenient stovetop configuration, allowing users to position pots and pans of different sizes easily. The grates are designed for stability, enhancing safety and usability. Additionally, the stove’s compatibility with various cooking methods makes it a versatile choice for any culinary enthusiast.

In conclusion, Desa CGS2718N combines high performance, user-friendly design, and safety features to meet the needs of today's cooks. Its advanced burner technology, combined with a stylish appearance and practical safety measures, positions it as a valuable addition to any kitchen. Whether for everyday meals or gourmet cooking, the Desa CGS2718N delivers exceptional results and a satisfying cooking experience.