Desa CGS2718N installation manual Minimum clearances shown in when using hood

Page 11

INSTALLING

Continued

Minimum Non Combustible Material Clearances

If Using Mantel

You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non combustible material behind it. Non combustible material must extend at least 8 inches up (for all models). If non combustible material is less than 12", you must install the fireplace hood acces- sory (24" model only). Even if non combustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See chart below and Figures 6 and 7 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Acces- sory for Vented Operation, page 13.

Non-Combustible

Requirements for

Material Distance (A)

Safe Installation

12" or more

Non combustible material okay.

Between 8" and 12"

24" Model: Install fireplace hood acessory (GA6050

 

or GA6052, see Accessories, page 29).

 

18" Model: Non combustable material okay.

Less than 8"

Non combustible material must be extended to at

 

least 8". See Between 8" and 12", above. If you

 

cannot extend material, you must operate heater

 

with flue damper open.

Mantel Clearances

If you meet minimum clearance between mantel shelf and top of fireplace open- ing, a hood is not required (see Figure 6).

Mantel Shelf

10"

Underside of

 

8"

 

 

Mantel Shelf

 

 

 

 

 

6"

 

 

 

 

2 1/2"

 

 

 

 

 

 

 

All minimum

 

 

 

 

distances are

 

 

 

 

in inches

Minimum Non-

(A)

 

 

 

Combustible

 

 

Log Set

 

 

 

Material

 

 

 

12"

20"

241/2" 271/2" 30"

24" Model

 

 

8"

14"

163/4" 181/2" 20"

18" Model

 

 

 

 

Top of Fireplace

 

 

 

 

Opening

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

If above minimum clearances are not met, you must have a hood. Follow

minimum clearances shown in Figure 7 when using hood.

Continued

 

102988

11

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Burner patterns can cause sooting Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Pilot OperationProviding Adequate Ventilation AIR forVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallingMinimum Wall and Ceiling Clearances see Figure Minimum Fireplace ClearanceLOG Sizing Requirements Minimum Non Combustible Material Clearances Minimum clearances shown in when using hood Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyMounting Bracket Connecting to GAS Supply Gas Connection Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsInstalling Operating Heater For Your Safety Read Before LightingOperating HeaterPilot Flame Pattern Inspecting BurnersODS/PILOT and Burner CleaningMaintenance Trouble ShootingTROUBLE- Shooting Maintenance,Refer to Air for Com Gas leak. See Warning Model Technical ServiceService Hints Parts Central Parts Under WarrantyParts Not Under Warranty Hood GA6052 AccessoriesValve GA5010 Hood GA6050Illustrated Parts Breakdown CGS2718N CGS3124N Parts ListKeep this Warranty Warranty Information

CGS2718N specifications

Desa CGS2718N is an innovative gas stove designed to enhance cooking efficiency and convenience in modern kitchens. This versatile appliance combines advanced technology with thoughtful design, catering to the needs of both amateur cooks and professional chefs.

One of the standout features of the CGS2718N is its powerful burners. Equipped with multiple high-efficiency burners, it ensures even heat distribution for optimal cooking results. The stove supports high-temperature cooking which is essential for tasks such as searing meats or achieving a perfect stir-fry. The burners also feature adjustable flame control, allowing users to customize heat levels with precision.

In terms of design, the CGS2718N boasts a sleek and modern aesthetic that fits seamlessly into various kitchen styles. The stainless steel surface is easy to clean and resistant to stains, ensuring that the stove maintains its elegant appearance over time. Its compact size makes it ideal for kitchens with limited space, while still providing ample cooking area.

Another notable characteristic of the CGS2718N is its safety features, which include flame failure devices that automatically shut off the gas supply if a flame is extinguished. This ensures peace of mind for families, especially in households with children or pets. Moreover, the stove is equipped with an ignition system that provides a reliable spark for easy, quick lighting without the need for matches.

The CGS2718N also includes a convenient stovetop configuration, allowing users to position pots and pans of different sizes easily. The grates are designed for stability, enhancing safety and usability. Additionally, the stove’s compatibility with various cooking methods makes it a versatile choice for any culinary enthusiast.

In conclusion, Desa CGS2718N combines high performance, user-friendly design, and safety features to meet the needs of today's cooks. Its advanced burner technology, combined with a stylish appearance and practical safety measures, positions it as a valuable addition to any kitchen. Whether for everyday meals or gourmet cooking, the Desa CGS2718N delivers exceptional results and a satisfying cooking experience.