Desa CGS2718N installation manual Ventilation AIR, Ventilation Air From Inside Building

Page 7

AIR FOR

WARNING

COMBUSTION

 

If the area in which the heater may be operated is smaller than that

 

AND

defined as an unconfined space, provide adequate combustion and

ventilation air by one of the methods described in the National Fuel

VENTILATION

Gas Code, ANSI Z223.1, 1992, Section 5.3 or applicable local codes.

Continued

VENTILATION AIR

 

 

Ventilation Air From Inside Building

 

This fresh air would come from an adjoining unconfined space. When ventilating to an

 

adjoining unconfined space, you must provide two permanent openings: one within 12"

 

of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see

 

options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3,

 

Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air

 

for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

 

 

12"

Ventilation

 

Ventilation Grills

Grills

 

Into Adjoining

Or

Into Adjoining Room,

Room,

Option 2

Remove

Option 1

 

Door into

 

 

 

 

Adjoining

 

 

Room,

 

 

Option

 

 

3

 

 

 

12"

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.

 

Outlet

Ventilated

 

 

Attic

 

 

Air

 

 

 

 

Outlet

 

 

 

Air

 

To Attic

 

 

 

 

 

 

To

 

 

 

Crawl

 

Inlet

 

Space

 

 

 

 

Air

 

 

 

 

Inlet Air

Ventilated

 

 

Crawl Space

 

 

 

 

Figure 3 - Ventilation Air from Outdoors

7

102988

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Burner patterns can cause sooting Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Pilot OperationVentilation AIR forProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallingLOG Sizing Requirements Minimum Fireplace ClearanceMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances Minimum clearances shown in when using hood Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyMounting Bracket Connecting to GAS Supply Gas Connection Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsInstalling Operating Heater For Your Safety Read Before LightingOperating HeaterPilot Flame Pattern Inspecting BurnersODS/PILOT and Burner CleaningMaintenance Trouble ShootingTROUBLE- Shooting Maintenance,Refer to Air for Com Gas leak. See Warning Service Hints Technical ServiceModel Parts Not Under Warranty Parts Under WarrantyParts Central Hood GA6052 AccessoriesValve GA5010 Hood GA6050Illustrated Parts Breakdown CGS2718N CGS3124N Parts ListKeep this Warranty Warranty Information

CGS2718N specifications

Desa CGS2718N is an innovative gas stove designed to enhance cooking efficiency and convenience in modern kitchens. This versatile appliance combines advanced technology with thoughtful design, catering to the needs of both amateur cooks and professional chefs.

One of the standout features of the CGS2718N is its powerful burners. Equipped with multiple high-efficiency burners, it ensures even heat distribution for optimal cooking results. The stove supports high-temperature cooking which is essential for tasks such as searing meats or achieving a perfect stir-fry. The burners also feature adjustable flame control, allowing users to customize heat levels with precision.

In terms of design, the CGS2718N boasts a sleek and modern aesthetic that fits seamlessly into various kitchen styles. The stainless steel surface is easy to clean and resistant to stains, ensuring that the stove maintains its elegant appearance over time. Its compact size makes it ideal for kitchens with limited space, while still providing ample cooking area.

Another notable characteristic of the CGS2718N is its safety features, which include flame failure devices that automatically shut off the gas supply if a flame is extinguished. This ensures peace of mind for families, especially in households with children or pets. Moreover, the stove is equipped with an ignition system that provides a reliable spark for easy, quick lighting without the need for matches.

The CGS2718N also includes a convenient stovetop configuration, allowing users to position pots and pans of different sizes easily. The grates are designed for stability, enhancing safety and usability. Additionally, the stove’s compatibility with various cooking methods makes it a versatile choice for any culinary enthusiast.

In conclusion, Desa CGS2718N combines high performance, user-friendly design, and safety features to meet the needs of today's cooks. Its advanced burner technology, combined with a stylish appearance and practical safety measures, positions it as a valuable addition to any kitchen. Whether for everyday meals or gourmet cooking, the Desa CGS2718N delivers exceptional results and a satisfying cooking experience.