Desa CGN10RLA installation manual OWNER’S Operation and Installation Manual

Page 1

INFRARED VENT-FREE NATURAL GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

CGN10RLA

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by

a qualified installer, service agency, or the gas supplier.

WARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage. Re- fer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxy- gen) from the room in which it is installed. Provisions for ad- equate combustion and venti- lation air must be provided. Refer to Air For Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufac- tured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualNatural GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationInstalling Heater to Wall Check GAS TypeInstalling Bottom Mounting Screw Installing Two Mounting ScrewsPlacing Heater on Mounting Screws Removing Front Panel of HeaterGas Connection Connecting to GAS SupplyPressure Testing Gas Supply Piping System For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS To ApplianceInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingTurn control knob until it locks at desired Observed Problem Possible Cause Replacement Parts SpecificationsTechnical Service Service HintsBaltimore Electric Washer Equipment Co Dayton Hardware Parts CentralsTarantin Tank Co Heater and Fireplace Store Cans Unlimited, IncCGN10RLA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListWarranty Information

CGN10RLA specifications

Desa CGN10RLA is a cutting-edge generator that exemplifies modern engineering and design, making it a popular choice among residential and commercial users alike. This generator stands out for its reliability and efficiency, characteristics that are essential for those who require a consistent power supply in various situations, from home use during outages to outdoor recreational activities.

One of the main features of the Desa CGN10RLA is its robust engine, which delivers a powerful output of up to 10,000 watts. This high capacity makes it suitable for running heavy-duty appliances and tools. Whether you need to power your air conditioning unit during a summer heatwave or run multiple devices on a construction site, this generator has the power to meet your needs.

The CGN10RLA also boasts impressive fuel efficiency. Its advanced fuel management system allows for longer run times on a single tank, which is a significant advantage for users looking to minimize interruptions and maximize productivity. This generator is designed to accommodate a variety of fuel types, providing flexibility and convenience for users.

Equipped with a state-of-the-art inverter technology, the Desa CGN10RLA guarantees stable power output with less than 3% total harmonic distortion. This feature is particularly important for sensitive electronic devices, ensuring that they are safeguarded against power surges that could lead to damage. Thus, users can confidently run their office equipment, computers, and other delicate electronics without concern.

Portability is another highlight of the CGN10RLA. The generator is designed with integrated wheels and a folding handle, making it easy to transport. Its compact size means it can fit into tight storage spaces, while still providing ample power when needed.

In terms of safety, the Desa CGN10RLA incorporates several protective features such as low oil shutdown and overload protection, ensuring the safe operation of the unit. This generator is also equipped with a user-friendly control panel, allowing for straightforward operation and accessibility.

Overall, the Desa CGN10RLA is a versatile generator that combines power, efficiency, and convenience. Whether for home use, travel, or professional projects, its advanced technology and user-centric design make it an excellent choice for anyone in need of reliable power.