EPSON Stylus Scan 2500

Revision A

Position mark

 

Forward =

Backward =

Gap widens

Gap narrows

+ side

 

 

Side frame

- side

Right parallelism

adjustment

bushing

PG lever

Figure 5-2. Parallelism Adjustment

5.3 Using the Service-Adjustment Program

For the Stylus Scan, instead of an exclusive service-adjustment program, you need to use the production program when performing certain service operations.

This program is necessary to eliminate any malfunction or fluctuation between individual printer mechanisms and printer parts. Therefore, any time you replace the printer mechanism, printhead, or main board you need to enter the correct information in the main board using this production program.

5.3.1 Installing the program

1.Insert the floppy disk in the "A" drive and open the "A" drive folder from My Computer or the Explorer.

2.Click the program icon for the Adjustment program.

NOTE: The program name varies according to model and program version. At the time of the publication, SS 2000 = N90B01W and SS2500 = P00B01W

3.Select an installation folder and click OK.

Printhead nozzle surface

Overlap = 0.5mm or more

Cleaner blade

Figure 5-3. Overlap of Head Surface and Cleaner Blade

Adjustment

Using the Service-Adjustment Program