EPSON Stylus Scan 2500 Revision A

Adjustment Using the Service-Adjustment Program 116

Figure 5-2. Parallelism Adjustment

Figure 5-3. Overlap of Head Surface and Cleaner Blade

5.3 Using the Service-Adjustment Program
For the Stylus Scan, instead of an exclusive service-adjustment program, you
need to use the production program when performing certain service
operations.
This program is necessary to eliminate any malfunction or fluctuation
between individual printer mechanisms and printer parts. Therefore, any time
you replace the printer mechanism, printhead, or main board you need to
enter the correct information in the main board using this production
program.

5.3.1 Installing the program

1. Insert the floppy disk in the "A" drive and open the "A" drive folder
from My Computer or the Explorer.
2. Click the program icon for the A djustment program.
NOTE: The program name varies according t o model and program
version. At the time of the publication, SS 2000 = N90B01W
and SS2500 = P00B01W
3. Select an installation folder and click OK.
Position mark
Forward =
Gap widens Backward =
Gap narrows
Side frame
+ side
- side
PG lever
Right parallelism
adjustment
bushing
Printhead nozzle
surface Cleaner blade
Overlap =
0.5mm or
more