EPSON Stylus Scan 2500 Revision A
Disassembly & Assembly Disassembling the Printer Mechanism 99
4.6.3 Removing the CR Motor Assembly
1. Remove the housing. (Refer to Section 4.3)
2. Rotate the gear 73.6 toward you and release the carriage lock mechanism,
then move the carriage to the center.
3. Pull out the circuit board tray as described in “Removal of the Circuit
Board Tray” on pag e90, and disconnect the CR motor cable from CN7.
4. Loosen the timing belt by pushing the driven pulley holder and remove
the timing belt from the pulley on the CR motor.
5. Remove two screws (CBS 3x6) and remove the CR motor assembly.
Figure 4-6. Removing the Timing Belt
Figure 4-7. Removing and Installing the CR Motor Assembly
CHECK
POINT
After installing the CR motor assembly, make sure that
two protrusions on the motor bracket are aligned with
the location holes in the frame. (Refer to Figure 4-7.)
Compression Spring 19.6 Driven Pulley Assembly
Timing Bell
To the Exterior
of Side Frame
To the Interior of
Side Frame
Driven Pulley
Holder
(No.1)
Make sure that protrusions of CR frame are in the holes of
frame when installing the CR motor assembly.