4.7.1 Removing the scanner

You only need to remove the scanner from the scanner support frame when replacing the scanner mechanism. You do not need to remove the scanner from the support frame when servicing

 

The printer mechanism

 

The circuit boards

 

Any motors

T

Scanner parts such as the glass and lamp.

To remove the scanner, see the following.

1.Remove the rear cover and top cover as described in “Removing the Housing” on pag e82.

2.Pull out the circuit board tray as described in “Removal of the Circuit Board Tray” on pag e90.

3.Disconnect the scanner FFC (CN14).

4.Remove two screws (CBS 3x6) securing the tension spring and base and unhook one end of the tension spring.

5.Remove the CR belt by pushing in the tension spring end and rotating the belt while pulling it laterally away from the driven pulley.

6.Flip the scanner over so that it is upside down and resting on the ASF. Use pliers to remove the CR belt clamp.

7.Slide the scanner CR guide shaft out of the bracket and slide the scanner

off the free end of the CR guide shaft.

4.7.1.1 Removing the lamp

You do not have to remove the scanner mechanism to replace the lamp.

1.Remove the rear cover and top cover as described in “Removing the Housing” on page 82.

2.Remove two black screws (CBP 3x8 with flange) securing the scanner cover.

 

Lift

Lift

here.

 

here.

 

Remove two screws.

3.Lift the cover by the sides.

4.Remove one connector from CN2.