4.3.2 Removing the top cover

1.Remove the rear cover as described above.

2.Remove the Document cover, the Maintenance cover, and the optional interface cover.

3.Move the scanner mechanism towards the middle of the Stylus Scan.

4.Remove three screws

Remove three CBS 3x6 screws.

5.Lift the top cover from the screw-side and slide it away from you so that the hooks clear the frame on the opposite side.

4.3.3 Removing the control panel assembly

The control panel assembly is replaced as one piece; there is no board-level repair.

1.Remove the rear cover and top cover as described in the two previous sections.

2.Remove two screws (CBS 3x10) and slightly pull out the control panel assembly.

3.Remove the FFC.

CA U When re-inserting the FFC into the control panel board connector, make sure the FFC is fully inserted but do not use too much force.

Also, the connector is difficult to see properly so it is easy to scrape or peel off the connecting strips at the end of the FFC. You need to check the strips at the end of the FFC for wear, folds, and tears every time you remove the FFC.

Disassembly & Assembly

Removing the Housing

83

Page 84
Image 84
Epson Scan 2500 service manual Removing the top cover, Removing the control panel assembly, Remove three CBS 3x6 screws