EPSON Stylus Scan 2500

Revision A

Axis of

Gear A

Paper

 

eject

 

roller

 

Gear B

Compression

spring

Gear C

Pump drive

roller

Figure 2-15. Pump Mechanism Power Transmission Process

The table below shows PF/Pump motor rotational direction and pump system operation.

Pump Motor Rotation and Function

PF motor pinion gear rotation

Pump unit operation

(looking at gear surface)

 

 

 

Clockwise (CW)

1)

Release the tubes

2)

Disengage Head Cleaner

forward rotation

3)

Disengage carriage lock

 

 

 

 

Counterclockwise (CCW)

1)

Squeeze tubes to pump ink

2)

Engage Head cleaner

backward rotation

3)

Engage carriage lock

 

 

 

 

Refer to Figure 2-16 in the right column which shows the pump operations at clockwise and counterclockwise rotation.

During ink-absorptive operations such as cleaning and flushing (but not during normal printing), ink drains from the ink cartridge to the waste-ink pads through the cap. During printing and flushing, ink is fired out of the nozzles by the PZT. But during absorption operations the head is capped and ink is sucked off the nozzle plate by the force of the vacuum created by the pump drive and the PZT does not move.

Operating Principles

Printer Mechanism Operation

47

Page 47
Image 47
Epson Scan 2500 service manual Pump Motor Rotation and Function, Gear B Compression Spring Gear C Pump drive Roller