EPSON Stylus Scan 2500 Revision A

Troubleshooting Scanner Troubleshooting 70

3.3 Scanner Troubleshooting

This section describes troubleshooting from the abnormal phenomenon. You

can isolate the faulty unit based on the abnormal phe nomenon. See

Table 3-6, “Service Level Troubleshooting Starts Here,” on page 69 to find the

closest phenomenon and the corresponding table to refer to.

Table 3-5. User-level Scanner-Specifi c errors

Error Cause Solution

Fatal error
The lamp is broken.
Stylus Scan turned on before
the transportation scr ew was
removed.
System breakdown.
Turn off the Stylus Scan and
turn it back on. If the error does
not clear, service.
(Disposition)
Turn off the lamp and stop
operation. Set bit 7 of the
status byte.
ADF paper
jam ADF fails to eject the document.
After removing the document,
turn the Stylus Scan off and
back on, or send the ESC @
command.
Parallel I/F init: active pulse
(Disposition)
Turn off the lamp and stop
operation. Set bit 7 of the
status byte.
Command
error
Unidentified command detected.
(Disposition)
The scanner sent a NACK signal
and is waiting for the next
command. If an incorrect
command or parameter is
received, it is disregarded and the
previous value is maintained.
Send a correct command to
clear the error.
ADF cover
open ADF cover open Close the cover.
Maintenance
cover open Maintenance cover open Close the cover.

Table 3-6. Service Level Troubleshooting Starts Here

Phenomenon Description Ref, Table
Scanner does not
operate with power on.
The Operate light on the control
panel does not come on.
Scanner does not operate the
initialization.
Table 3-7
Table 3-8
Fatal Error occurs and
is not cleared afte r
turning off and back on
the scanner.
Carriage unit does not operate.
Carriage unit crashes into the
frame, and an error is indicated.
The lamp does not light up.
Table 3-9
Table 3-10
Table 3-11
Scanned image is
unclear. --- Table 3-12
“Interface Error” is
indicated.
SCSI Interface Error
USB Interface Error Table 3-13
Table 3-14
“Option Error” occurs.
Optional unit(ADF/TPU)
do not operate.
Optional unit does not operate
correctly. Table 3-15

Table 3-7. Power problems

Cause Step Checkpoint Finding Solution
Connector CN1 on
the power board is
disconnected. 1
Is the connector
CN1 on the power
board
disconnected?
Yes Connect CN1
properly.
Connector CN1 or
CN2 on the power
board
disconnected.
2
Is the connector
CN1 or CN2 on
the power board
disconnected?
Yes Connect CN1 or 2
properly.
Fuse on the power
board has blown
out. 3Has the fuse on
the power board
blown out? Yes Replace the fuse.