Table 1-13. Server Module Messages (continued)
Message | Causes | Corrective Actions |
|
|
|
Plug & Play Configuration | Error encountered in initializing PCI | Set the NVRAM_CLR switch to "on" |
Error | device; faulty server module board. | and reboot the server module. See |
|
| Figure |
|
| Check for a BIOS update. If the problem |
|
| persists, see "Getting Help" on page 127. |
|
|
|
Read fault | Faulty diskette, diskette drive, optical | Replace the diskette. Ensure that the |
| drive, or hard drive. | custom cable is properly connected. See |
|
| "Troubleshooting USB Devices" on |
|
| page 105 or "Troubleshooting Hard |
|
| Drives" on page 113. for the appropriate |
|
| drive(s) installed in your system. |
|
|
|
Remote Configuration | Server module could not implement | Retry Remote Configuration. |
update attempt failed | Remote Configuration request. |
|
|
|
|
Sector not found | Faulty diskette or hard drive. | Replace the diskette. If the problem |
Seek error |
| persists, see "Troubleshooting Hard |
| Drives" on page 113 for the appropriate | |
Seek operation failed |
| |
| drive installed in your system. | |
|
| |
|
|
|
Shutdown failure | Shutdown test failure. | Ensure that all memory modules are |
|
| properly installed. See "Troubleshooting |
|
| Server Module Memory" on page 112. If |
|
| the problem persists, see "Getting Help" |
|
| on page 127. |
|
|
|
Spare bank enabled | Memory sparing enabled. | Information only. |
|
|
|
The amount of system | Faulty memory module. | See "Troubleshooting Server Module |
memory has changed. |
| Memory" on page 112. If the problem |
|
| persists, see "Getting Help" on page 127. |
| Information only, if you have changed |
|
| the memory configuration. |
|
See "Troubleshooting Server Module Memory" on page 112. If the problem persists, see "Getting Help" on page 127.
Incorrect Time or Date settings; faulty | |
please run SETUP program | server module board battery. |
Check the Time and Date settings. See "Using the System Setup Program" on page 43. If the problem persists, see "Troubleshooting the Server Module Battery" on page 115.
Timer chip counter 2 | Faulty server module board. | See "Getting Help" on page 127. |
failed |
|
|