Table 1-13. Server Module Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Plug & Play Configuration

Error encountered in initializing PCI

Set the NVRAM_CLR switch to "on"

Error

device; faulty server module board.

and reboot the server module. See

 

 

Figure 6-2 for switch location.

 

 

Check for a BIOS update. If the problem

 

 

persists, see "Getting Help" on page 127.

 

 

 

Read fault

Faulty diskette, diskette drive, optical

Replace the diskette. Ensure that the

 

drive, or hard drive.

custom cable is properly connected. See

 

 

"Troubleshooting USB Devices" on

 

 

page 105 or "Troubleshooting Hard

 

 

Drives" on page 113. for the appropriate

 

 

drive(s) installed in your system.

 

 

 

Remote Configuration

Server module could not implement

Retry Remote Configuration.

update attempt failed

Remote Configuration request.

 

 

 

 

Sector not found

Faulty diskette or hard drive.

Replace the diskette. If the problem

Seek error

 

persists, see "Troubleshooting Hard

 

Drives" on page 113 for the appropriate

Seek operation failed

 

 

drive installed in your system.

 

 

 

 

 

Shutdown failure

Shutdown test failure.

Ensure that all memory modules are

 

 

properly installed. See "Troubleshooting

 

 

Server Module Memory" on page 112. If

 

 

the problem persists, see "Getting Help"

 

 

on page 127.

 

 

 

Spare bank enabled

Memory sparing enabled.

Information only.

 

 

 

The amount of system

Faulty memory module.

See "Troubleshooting Server Module

memory has changed.

 

Memory" on page 112. If the problem

 

 

persists, see "Getting Help" on page 127.

 

Information only, if you have changed

 

 

the memory configuration.

 

Time-of-day clock stopped Faulty battery; faulty server module board.

See "Troubleshooting Server Module Memory" on page 112. If the problem persists, see "Getting Help" on page 127.

Time-of-day not set -

Incorrect Time or Date settings; faulty

please run SETUP program

server module board battery.

Check the Time and Date settings. See "Using the System Setup Program" on page 43. If the problem persists, see "Troubleshooting the Server Module Battery" on page 115.

Timer chip counter 2

Faulty server module board.

See "Getting Help" on page 127.

failed

 

 