Table 1-13. Server Module Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Memory address line

Faulty or improperly installed memory

Ensure that all memory modules are

failure at address, read

modules, or faulty server module

properly installed. See "Troubleshooting

value expecting value

board.

Server Module Memory" on page 112. If

Memory double word logic

 

the problem persists, see "Getting Help"

 

on page 127.

failure at address, read

 

 

 

value expecting value

 

 

Memory odd/even logic

 

 

failure at start address

 

 

to end address

 

 

Memory write/read failure

 

 

at address, read value

 

 

expecting value

 

 

 

 

 

Memory mirroring enabled

Memory mirroring enabled

Information only.

 

 

 

Memory tests terminated by

The spacebar was pressed during

Information only.

keystroke

POST to terminate the memory test.

 

 

 

 

No boot device available

Faulty or missing diskette drive,

Check the Integrated Devices

 

optical drive, or hard drive.

configuration settings in the System

 

 

Setup program and ensure that the

 

 

controller for the boot device is enabled.

 

 

See "Using the System Setup Program"

 

 

on page 43. Ensure that the controller

 

 

for the boot device is enabled.

 

 

If the problem persists, replace the drive.

 

 

See "Hard Drives" on page 89.

 

 

 

No boot sector on

An operating system is not on the

Check the hard-drive configuration

hard-disk drive

hard drive.

settings in the System Setup program.

 

 

See "Using the System Setup Program"

 

 

on page 43.

 

 

 

No timer tick interrupt

Faulty server module board.

See "Getting Help" on page 127.

 

 

 

Not a boot diskette

Not a bootable diskette.

Use a bootable diskette.

 

 

 

PCI BIOS failed to install

Faulty or improperly installed.

Reseat the daughter card. See "I/O

 

 

Module Daughter Card" on page 82. If

 

 

the problem persists, see "Getting Help"

 

 

on page 127.