Table 1-13. Server Module Messages (continued)
Message | Causes | Corrective Actions |
|
|
|
Memory address line | Faulty or improperly installed memory | Ensure that all memory modules are |
failure at address, read | modules, or faulty server module | properly installed. See "Troubleshooting |
value expecting value | board. | Server Module Memory" on page 112. If |
Memory double word logic |
| the problem persists, see "Getting Help" |
| on page 127. | |
failure at address, read |
| |
|
| |
value expecting value |
|
|
Memory odd/even logic |
|
|
failure at start address |
|
|
to end address |
|
|
Memory write/read failure |
|
|
at address, read value |
|
|
expecting value |
|
|
|
|
|
Memory mirroring enabled | Memory mirroring enabled | Information only. |
|
|
|
Memory tests terminated by | The spacebar was pressed during | Information only. |
keystroke | POST to terminate the memory test. |
|
|
|
|
No boot device available | Faulty or missing diskette drive, | Check the Integrated Devices |
| optical drive, or hard drive. | configuration settings in the System |
|
| Setup program and ensure that the |
|
| controller for the boot device is enabled. |
|
| See "Using the System Setup Program" |
|
| on page 43. Ensure that the controller |
|
| for the boot device is enabled. |
|
| If the problem persists, replace the drive. |
|
| See "Hard Drives" on page 89. |
|
|
|
No boot sector on | An operating system is not on the | Check the |
hard drive. | settings in the System Setup program. | |
|
| See "Using the System Setup Program" |
|
| on page 43. |
|
|
|
No timer tick interrupt | Faulty server module board. | See "Getting Help" on page 127. |
|
|
|
Not a boot diskette | Not a bootable diskette. | Use a bootable diskette. |
|
|
|
PCI BIOS failed to install | Faulty or improperly installed. | Reseat the daughter card. See "I/O |
|
| Module Daughter Card" on page 82. If |
|
| the problem persists, see "Getting Help" |
|
| on page 127. |