6If you removed a daughter card from the server module board, reinstall it. See "Installing a Daughter Card" on page 82.
7Close the server module. See "Closing the Server Module" on page 76.
8Install the server module. See "Installing a Server Module" on page 74.
9Enter the System Setup program to confirm that the battery is operating properly. See "Using the System Setup Program" in your User's Guide.
10Enter the correct time and date in the System Setup program's Time and Date fields.
11Exit the System Setup program.
12To test the newly installed battery, remove the server module for at least an hour. See "Removing a Server Module."
13After an hour, install the server module. See "Installing a Server Module."
14Enter the System Setup program and if the time and date are still incorrect, see "Getting Help" for instructions about obtaining technical assistance.
Hard Drives
Each server module supports one or two
NOTICE: You cannot install a SAS drive and a SATA drive within a given server module (blade). However, you can install server modules (blades) with SAS drives and server modules with SATA drives in the same server enclosure.
Integrated Mirroring of Hard Drives
The controller on the server module board supports integrated mirroring if two drives are installed. After installing the drives, see your Configuration Guide to enable and configure your RAID array.
Installing a Previously Arrayed Hard Drive Into a
A hard drive previously installed in a RAID configuration contains partial segments of information referred to as
CAUTION: Do not attempt to rebuild the degraded array in a
To remove the
1Back up all data onto the replacement hard drive.
2Restart the server module and press <Ctrl><C> to run the RAID configuration utility.
3Change the degraded array properties from mirror to SAS mode by selecting NO as the Mirror option.
Installing System Options