About Your System 19
Power Supply Indicator

Each hot-pluggable power supply has indicators that provide information about power status, fault, and

the presence of AC power (see Figure1-6). Table 1-5 lists the power supply indicator codes.

NOTE: Only 2100-W power supply modules are supported on your system. The 2100-W power supply modules
require 180–240 V input from a PDU capable of providing AC current up to 29.2 A at 180 V input. If the power supply
modules are plugged into 110-V electrical outlets, the system will not power up.
Table 1-4. Back-Panel Features and Indicators
Component Indicator Description
Power supply modules Provide information about power status (see "Power Supply Indicator Codes" on
page20).
Fan modules Provide information about status of the system fans (see "Fan Module Indicators"
on page21).
KVM module Provides information about the KVM module (see "KVM Modules" on page22).
DRAC/MC module Provides information about system status, system management status, and port
status (see "DRAC/MC Module" on page26).
PowerConnectâ„¢ 5316M
Ethernet switch module
Provides information about the 10/100/1000 BASE-T network status (see
"PowerConnect 5316M Ethernet Switch Module" on page29).
Fibre Channel pass-through
module
Provides information about the Fibre Channel network status (see "Fibre
Channel Pass-Through Module" on page31).
Fibre Channel switch module Provides information about the Fibre Channel network status (see "Fibre
Channel Switch Module" on page32).
Infiniband pass-through
module
Provides information about the Infiniband network status (see "Infiniband Pass-
through Module" on page32).
Gb pass-through module Provides information about the network status (see "Gb Ethernet Pass-through
Module" on page33).