Table 1-13. Server Module Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Error: Memory failure

Faulty or improperly seated memory

See "Troubleshooting Server Module

detected. Memory size

modules.

Memory" on page 112.

reduced. Replace the

 

 

faulty DIMM as soon as

 

 

possible.

 

 

 

 

 

Error: Remote Access

Faulty or improperly installed

Reinstall the DRAC/MC module. See

Controller initialization

DRAC/MC module.

"DRAC/MC Module" on page 26.

failure.

 

If the problem persists, replace the

 

 

 

 

DRAC/MC module.

FBD training error: The following branch has been disabled: Branch x.

The specified branch (channel pair) contains DIMMs that are incompatible with each other.

Ensure that only Dell qualified memory is used. Dell recommends purchasing memory upgrade kits directly from http://www.dell.com or your Dell sales agent to ensure compatibility.

Gate A20 failure

Faulty keyboard controller (faulty

See "Getting Help" on page 127.

 

server module board).

 

 

 

 

General failure

Operating system corrupted or

Reinstall the operating system.

 

improperly installed.

 

 

 

 

Keyboard controller

Faulty keyboard controller (faulty

See "Getting Help" on page 127.

failure

server module board).

 

 

 

 

Keyboard data line failure

Loose or improperly connected

Ensure that the keyboard is properly

Keyboard failure

keyboard cable; faulty keyboard to the

connected. If the problem persists,

custom cable; faulty keyboard

replace the keyboard.

Keyboard stuck key failure

controller.

If the message still appears, the keyboard

 

 

 

 

controller is faulty. See "Getting Help"

 

 

on page 127.

 

 

 

Manufacturing mode

System is incorrectly configured.

Set the NVRAM_CLR switch to "on"

detected

 

and reboot the server module. See

 

 

Figure 6-2 for switch location.

About Your System

37

Page 37
Image 37