32 About Your System
Fibre Channel Switch Module
You can install one or two hot-pluggable Fibre Channel switch modules in I/O bay 3 and I/O bay 4,
beginning with I/O bay 3. You must also install a Fibre Channel HBA daughter card in the server module.
The Fibre Channel switch module includes four external autosensing Fibre Channel ports numbered 10
through 13, 10 internal ports, and one Ethernet port with an RJ-45 connector. All the external ports operate
at 1 Gb/sec, 2 Gb/sec, or 4 Gb/sec.
See the documentation for your particular Fibre Channel switch module for the functionality and
location of the switch module indicators. For general information on installing this module, see "Chassis
I/O Module" on page70.
NOTE: The Fibre Channel switch module includes Short Wave Small Form Factor Pluggable (SFP) optical
transceivers. To ensure proper functionality, use only SFPs provided with this module.
Infiniband Pass-through Module
The Infiniband pass-through module provides a bypass connection between an optional Infiniband Host
Channel Adapter (HCA) daughter card in the server module and 4x Infiniband Transceivers for direct
connection to an Infiniband switch. The Infiniband pass-through modules are hot-pluggable. To provide
redundancy, both I/O bay 3 and I/O bay 4 must have Infiniband pass-through modules installed. In this
configuration, the module in I/O bay 3 connects to port 1 on the Infiniband HCA daughter card; the
Infiniband pass-through module in I/O bay 4 connects to port 2 on the Infiniband HCA daughter card.
NOTE: The Infiniband pass-through module uses small form factor 4x Infiniband connectors. To ensure proper
functionality, use only cables provided with the module.
NOTE: If you require service, technical support, or parts replacement for your Topspin Infiniband product, contact
Topspin Support Services directly at 1-800-499-1473 or through www.topspin.com.
Table 1-11. Fibre Channel Pass-Through Module Indicators
Indicator Type Activity
Indicator
Indicator Code
Fibre Channel
indicator
(green/amber)
Off Power is off to the system.
Green/amber System has power.
Green/off Fibre Channel connection is online.
Off/amber The port is connected to a valid link partner on the network.
Off/flashing (twice
per second)
Connection has lost synchronization.