Sprnn]

The switcher initiates the Spr message when a memory preset has been saved from the front panel. “nn” is the preset number.

Rprnn]

The switcher initiates the Rpr message when a memory preset has been recalled from the front panel. “nn” is the preset number.

InnnAudxx]

The switcher initiates the Aud message when a front panel input audio level change has occurred. “n” is the input number and “xx” is the dB level.

OutnnVolxx]

The switcher initiates the Vol message when a front panel output audio volume change has occurred. nn is the output number and xx is the volume level.

Vmtnn*x]

The switcher initiates the Vmt message when an output video mute is toggled on or off from the front panel. nn is the output number and x is the mute status: 1 = on, 0 = off.

Amtnn*x]

The switcher initiates the Amt message when an output audio mute is toggled on or off from the front panel. nn is the output number and x is the mute status: 1 = on, 0 = off.

Exen]

The switcher initiates the Exe message when the front panel security lockout (executive mode) is toggled on or off from the front panel. “n” is the executive mode: 0, 1, or 2.

Switcher Error Responses

When the switcher receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the switcher is unable to perform the command because the command is invalid or contains invalid parameters, the switcher returns an error response to the host. The error response codes are:

E01 — Invalid input channel number (out of range)

E10 — Invalid command

E11 — Invalid preset number (out of range)

E12 — Invalid output number (out of range)

E13 — Invalid value (out of range)

E14 — Invalid command for this configuration

E17 — Timeout (caused only by direct write of global presets)

E22 — Busy

E24 — Privileges violation (Users have access to all view and read commands [other than the administrator password], and can create ties, presets, and audio mutes

E25 — Device not present

E26 — Maximum number of connections exceeded

E27 — Invalid event number

E28 — Bad filename / file not found

CrossPoint and MAV Series Matrix Switchers • Programming Guide 93

Page 99
Image 99
Extron electronic 450 manual Switcher Error Responses