Command and Response Table for SIS Commands (continued)

Command Function

SIS Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

 

 

 

 

 

 

 

 

Audio output volume

 

 

 

NOTE: Table 11, below, the commands defines the value of each audio volume step.

Set a specific audio volume

X@*X*V

OutX@VolX*]

Example:

1*50v

Out01Vol50]

Increment volume

X@+V

OutX@VolX*]

Example:

1+V

Out01Vol51]

Decrement volume

X@-V

OutX@VolX*]

Read output volume

X@V

X*]

Volume setting for output 7 is 50 (79)%. Increment volume by 1 step.

Decrease volume by 1 step.

 

 

 

 

Table 6.

Audio Volume Adjustment Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

value

dB of

 

Output

 

 

value

 

dB of

Output

 

value

dB of

Output

 

 

 

X8

 

 

X8

 

X8

 

 

 

attenuation

 

volume

 

 

attenuation

volume

attenuation

volume

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

76

 

0%

 

 

 

 

 

 

 

 

 

 

 

 

01

63

 

5.5%

 

 

23

 

41

38.5%

 

45

19

71.5%

 

 

02

62

 

7%

 

 

24

 

40

40%

 

46

18

73%

 

 

03

61

 

8.5%

 

 

25

 

39

41.5%

 

47

17

74.5%

 

 

04

60

 

10%

 

 

26

 

38

43%

 

48

16

76%

 

 

05

59

 

11.5%

 

 

27

 

37

44.5%

 

49

15

77.5%

 

 

06

58

 

13%

 

 

28

 

36

46%

 

50

14

79%

 

 

07

57

 

14.5%

 

 

29

 

35

47.5%

 

51

13

80.5%

 

 

08

56

 

16%

 

 

30

 

34

49%

 

52

12

82%

 

 

09

55

 

17.5%

 

 

31

 

33

50.5%

 

53

11

83.5%

 

 

10

54

 

19%

 

 

32

 

32

52%

 

54

10

85%

 

 

11

53

 

20.5%

 

 

33

 

31

53.5%

 

55

9

86.5%

 

 

12

52

 

22%

 

 

34

 

30

55%

 

56

8

88%

 

 

13

51

 

23.5%

 

 

35

 

29

56.5%

 

57

7

89.5%

 

 

14

50

 

25%

 

 

36

 

28

58%

 

58

6

91%

 

 

15

49

 

26.5%

 

 

37

 

27

59.5%

 

59

5

92.5%

 

 

16

48

 

28%

 

 

38

 

26

61%

 

60

4

94%

 

 

17

47

 

29.5%

 

 

39

 

25

62.5%

 

61

3

95.5%

 

 

18

46

 

31%

 

 

40

 

24

64%

 

62

2

97%

 

 

19

45

 

32.5%

 

 

41

 

23

65.5%

 

63

1

98.5%

 

 

20

44

 

34%

 

 

42

 

22

67%

 

64

0

100%

 

 

21

43

 

35.5%

 

 

43

 

21

68.5%

 

 

 

 

 

 

22

42

 

37%

 

 

44

 

20

70%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: X@ = Output number

 

01 16 or 32

 

 

 

 

 

 

 

X* = Volume

 

 

 

00

64 (1 dB per step except for 0-to-1, which is 13 dB). See table 11, above.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CrossPoint and MAV Series Matrix Switchers • Programming Guide 97