Command and Response Table for SIS Commands (continued)

Command Function

SIS Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

 

 

 

 

 

 

 

 

Names

 

 

 

NOTE: The HTML language reserves certain characters for specific functions (see Special Characters on page 109).

Write global preset name

EX(,X1!NG}

NmgX(,X1!]

Example:

E1,Security 1NG}

Nmg01,Security 1]

Read global preset name

EX(NG}

X1!]

Example:

E2NG}

Security 2]

Write room preset name

EX1)*X(,X1!NP}

NmpX1)*X(,X1!]

Example:

E1*3,Podium_DVDNP}

Nmp01*3,Podium_DVD]

Name global preset 1 “Security 1”.

Name room 1, preset 3 “Podium_ DVD”.

Read room preset name

EX1),X(NP}

X1!]

NOTES:

Do not use leading spaces in preset names.

If a preset is unassigned, the X1! displays [unassigned].

If a global preset is saved, but not yet named, the default name is Preset X(.

If a room preset is saved, but not yet named, the default name is RmX1) PrstX(.

Write input name

EX!,X1!NI}

NmiX$,X1!]

 

Example:

E1,Podium camNI}

Nmi01,Podium cam]

Name input 1 “Podium cam”.

Read input name

EX$NI}

X1!]

 

Write output name

EX@,X1!NO}

NmoX@,X1!]

 

Example:

E1,Main PJ1NO}

Nmo01,Main PJ1]

Name output 1 “Main PJ1”.

Read output name

EX@NO}

X1!]

 

Front panel locks

NOTE: See Setting the Front Panel Locks (Executive Modes) on page 75 for more information on the Lock modes.

Lock all front panel functions

1X

Lock advanced front panel functions

2X

Unlock all front panel functions

0X

View lock status

X

Exe1]

Exe2]

Exe0]

X#]

Enable Lock mode 1. Enable Lock mode 2. Enable Lock mode 0.

NOTE: X! = Input number (for tie)

00

– (maximum number of inputs for your model)

(00 = untied)

X@ = Output number

01

– (maximum number of outputs for your model)

X# = Lock mode

0 = mode 0

1 = mode 1

2 = mode 2

X( = Global or room preset number

00

- 32, 10 maximum for a room preset (00 = current configuration for view only)

X1) = Room number (for room presets)

10 max. (Each can have up to 10 presets (X(s) assigned.)

X1! = Name

12 characters (upper- and lower-case alphanumeric characters and / and spaces) max.

 

 

 

 

 

CrossPoint and MAV Series Matrix Switchers • Programming Guide 103

Page 109
Image 109
Extron electronic 450 manual Names