RS-232/RS-422
HRemote
REMOTE
1 | 6 | RS232/RS422 |
| ||
|
|
5 | 9 |
|
|
|
| Matrix Sizes: |
|
| |
|
|
| 84 through 1616 | Matrix Sizes: | ||
| All Models | MAV Plus 248 / 328 A | 2412 through 3232 | |||
Pin | Function | Function | Function | |||
1 | — | Not used | — | Not used | Tx+ | Transmit data (+) |
2 | Tx | Transmit data | Tx– | Transmit data | Tx– | Transmit data |
3 | Rx | Receive data | Rx– | Receive data | Rx+ | Receive data (+) |
4 | — | Not used | — | Not used | Rx– | Receive data |
5 | Gnd | Ground | Gnd | Ground | Gnd | Signal Ground |
6 | — | Not used | — | Not used | — | Not used |
7 | — | Not used | Rx+ | Receive data (+) | — | Not used |
8 | — | Not used | Tx+ | Transmit data (+) | — | Not used |
9 | — | Not used | — | Not used | — | Not used |
Figure 23. Remote RS-232/RS-422 Connector
See Programming Guide, beginning on page 89, for definitions of the SIS commands (serial commands to control the switcher via this connector) and Matrix Software, beginning on page 110, for details on how to install and use the control software.
NOTE: The switcher can support either the
If desired, connect an MKP 2000 or MKP 3000 remote control panel to the
CrossPoint and MAV Series Matrix Switchers • Installation 26