Performing Soft Resets —

CrossPoint 450 Plus and MAV Plus 2412, 2424, 3216, and 3232 Matrix Sizes

The whole switcher reset function is identical to the front panel system reset (see Performing a System Reset from the Front Panel on page 81) without requiring you to power down the switcher. This function is also identical to theEZXXX} SIS command defined on page 104. System reset clears all ties and presets, resets all audio gains to unity gain (+0dB), and resets volume to 100% (0dB of attenuation).

NOTE: The whole switcher reset does not reset the Internet protocol (IP) settings or replace user-installed firmware.

The absolute reset function is identical to EZQQQ} SIS command defined on page 104. Absolute reset performs all of the whole switcher reset functions and clears the IP address of the switcher to 192.168.254.254 and subnet mask to 255.255.0.0.

Perform soft resets as follows:

1.Use an Extron Tweeker or other small screwdriver to press and hold the Reset button until the front panel I/I buttons (RGBHV [CrossPoint switchers] or Video [MAV Plus switchers])) and Audio buttons blink once (reset whole switcher) or twice (absolute reset) (see figure 56).

Press and hold

Front panel I/O buttons flash once.

Release, then immediately

the Reset button.

press and release again.

 

 

 

I / O

 

RESET

5 seconds

RESET

Reset whole switcher

 

 

 

RGBHV

AUDIO

ETHERNET

LINK ACT

 

 

Press and hold

Front panel I/O buttons flash twice.

Release, then immediately

the Reset button.

press and release again.

 

 

 

I / O

 

RESET

10 seconds

RESET

Absolute reset

 

 

 

RGBHV

AUDIO

ETHERNET

LINK ACT

 

 

Figure 56. Whole Switcher and Absolute Resets

2.Release the Reset button and then immediately press and release the Reset button again. Nothing happens if the second momentary press does not occur within 1

second.

CrossPoint and MAV Series Matrix Switchers • Operation 81

Page 87
Image 87