X5# = Verbose mode

0

= clear/none (default for Telnet connection)

 

1

= verbose mode (default for RS-232/RS-422 connection)

 

2

= tagged responses for queries

 

3

= verbose mode and tagged for queries

NOTE: If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set command does (for example, the read matrix name command ECN}, returns Ipn•X3!]).

X5$ =

Flow control

hardware, software, none (only the first letter required)

X5%

=

Data pacing (in ms between bytes)

0000 (default) - 1000

X5^ =

Time (in 10 ms increments) to wait for characters

10 (= 100 ms, default) - 32767

X5& =

Time (in 10 ms increments) between characters

2

(= 20 ms, default) - 32767

X5*

=

Port timeout interval (in 10-second increments)

1

(= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)

SIS Command and Response Table for IP- and Remote Port-Specific Commands

Command Function

SIS Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

IP and Remote port setup commands

Set matrix name

Read matrix name (location)

Reset matrix name to factory default Set time and date

Read time and date Set GMT offset

Example: Read GMT offset

Set Daylight Savings Time

Read Daylight Savings Time Set IP address

Read IP address

Read hardware address Read # of open connections Set subnet mask

Read subnet mask

Set gateway IP address Read gateway IP address Set administrator password Read administrator password

Reset (clear) administrator password Set user password

Read user password

Reset (clear) user password Set mail server, domainname Read mail server, domainname Set e-mail recipient

EX6!CN}

IpnX3)]

ECN}

X3)]

ECN}

IpnX3!]

EX3@CT}

IptX3@]

ECT}

X3#]

EX3#CZ}

IpzX3#]

E8.3CZ}

Ipz+08:30]

ECZ}

X3$]

EX3%CX}

X3%]

ECX}

X3%]

EX3^CI}

IpiX3^]

ECI}

X3^]

ECH}

X3&]

ECC}

X3*]

EX3^CS}

IpsX3^]

ECS}

X3^]

EX3^CG}

IpgX3^]

ECG}

X3^]

EX3(CA}

IpaX3(]

ECA}

X3(]

ECA}

Ipa]

EX3(CU}

IpuX3(]

ECU}

X3(]

ECU}

Ipu]

EX3^,X4),X3(CM}

IpmX3^,X4),X3(]

ECM}

X3^,X4),X3(]

EX4!,X4@CR}

IprX4!,X4@,]

In the command, the divider between hours and minutes can be either a colon or a period. In the response, the divider is a colon.

8.3 = 8:30

Default: 192.168.254.254

Reads MAC address.

Default: 255.255.0.0

Default: 0.0.0.0

This command sets the recipient. To receive e-mail notifications, you must then set the events that the switcher reports, using one or more separate Set e-mail events (EM) commands (see the next page).

Example:

E72,Jsmith@folklore.netCR}

 

 

Ipr72,Jsmith@folklore.net,]

Read e-mail recipient

EX4!CR}

X4@,X4$]

CrossPoint and MAV Series Matrix Switchers • Programming Guide 108

Page 114
Image 114
Extron electronic 450 manual IP and Remote port setup commands, X5$ =