EPSON Stylus Scan 2500

Revision A

1.As long as the AC power cable is plugged into a power source, voltage flows through the primary side (bottom in figure above) of the power supply board.

2.The fuse prevents damage to the power supply board in case the current is too strong.

3.The filter circuit acts to filter incoming electrical noise and to smoothen the electrical current.

4.The full wave rectifier circuit converts AC to DC.

5.The smoothing circuit stabilizes out the DC wave.

6.The main switching circuit controls the flow of current to the transformer (hence to the entire secondary side). The main switching circuit, transformer, and feedback circuit work in combination like the heart, lungs, and brain (respectively) of the human body. The main switching circuit is the variable-flow generator like the heart, the transformer convert the power to a usable form like lungs adding oxygen to blood, and the feedback circuit controls the flow like the brain controlling the heartbeat/pulse.

7.The transformer receives approximate 100V or 220V DC (depending on the model) and steps the voltage down before sending it to the secondary side.

8.The current is stabilized as it goes through another smoothing circuit.

9.The 24V, 12V, 5V, and 3.3V regulators control the flow of current so that only the rated voltage flows through each regulator. The input level fluctuates but the output is constant.

10.The 42V, 24V, 12V, 5V, and 3.3V line over-voltage limitation protectors monitor their individual lines for any voltage over the rated amount. If over-current is detected, a signal is sent to the photo coupler to decrease current.

11.The +42V line constant control is similar to a regulator in that it is always working, but instead of fixing the over-current, it reports the over-current to the photo coupler.

12.The photo coupler is one part of the over-current feedback system. A photo coupler is necessary because electrical current cannot cross the from the primary side to the secondary side and vice-versa; the absolute

ground levels for the primary side (AC as well as DC) and secondary side (DC only) are different, so they will short if they come into contact. The photo coupler transmits signals via a photo emitter.

13.The feedback circuit 1) receives over-current information from the photo coupler by means of a photo receiver 2) monitors the transformer for over-current and 3) receives power-supply information/commands from the MAIN board and power switch. The feedback circuit changes the voltage sent from the main switching circuit to the transformer when necessary.

14.The power-drop delay circuit is a thirty-second timer that activates whenever the power is turned off. The thirty-second period is necessary to guarantee safe completion of the power-down sequence.

2.5.2 B102 MAIN Board

The B102 MAIN Board controls the printer, scanner, copy function, pumping, paper feeding, and all signals to/from the control panel unit. The following figure shows the MAIN Board circuit diagram for EPSON Stylus Scan 2500.

Operating Principles

Electrical Circuit Operating Principles

57

Page 57
Image 57
Epson Scan 2500 service manual 2 B102 Main Board