EPSON Stylus Scan 2500 Revision A
Troubleshooting Printer Related Troubleshooting 69
Printer stops during
initialization. Fatal error appears.
ASF sensor is defective. Check the signal level of the ASF sensor.
(Refer to Table 5-2) Replace ASF sensor.
PE sensor is defective. Check the signal level of the PE sensor.
(Refer to Table 5-2) Replace PE sensor.
HP sensor is defective. Check the signal level of the HP sensor.
(Refer to Table 5-2.)
Head FFC is disconnected. Check if the head FFC is connected. Connect the head FFC.
CR motor is defective. Check t he CR motor cable is connected. Replace the CR motor if there is no
problem in the cable connection.
PF motor is defective. Check if the PF motor cable is connected. Replace the PF motor if there is no
problem in the cable connection.
Table 3-4. Repair of the Printer Mechanism (cont.)
Symptom Condition Cause Check Point Solution