EPSON Stylus Scan 2500

 

 

 

 

Revision A

 

 

 

Table 3-4. Repair of the Printer Mechanism (cont.)

 

 

 

 

 

 

 

 

 

 

 

Symptom

Condition

 

Cause

Check Point

Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

ASF sensor is defective.

Check the signal level of the ASF sensor.

Replace ASF sensor.

 

 

 

 

 

 

(Refer to Table 5-2)

 

 

 

 

 

 

PE sensor is defective.

Check the signal level of the PE sensor.

 

 

 

 

 

 

(Refer to Table 5-2)

 

 

 

 

 

 

 

Replace PE sensor.

 

 

 

 

 

 

 

 

 

Printer stops during

 

 

HP sensor is defective.

Check the signal level of the HP sensor.

 

 

 

 

 

 

 

Fatal error appears.

 

(Refer to Table 5-2.)

 

 

 

 

 

 

 

 

initialization.

 

 

 

 

 

 

 

 

Head FFC is disconnected.

Check if the head FFC is connected.

Connect the head FFC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR motor is defective.

Check the CR motor cable is connected.

Replace the CR motor if there is no

 

 

 

 

 

problem in the cable connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PF motor is defective.

Check if the PF motor cable is connected.

Replace the PF motor if there is no

 

 

 

 

 

problem in the cable connection.

 

 

 

 

 

 

 

 

 

Troubleshooting

Printer Related Troubleshooting

69

Page 69
Image 69