EPSON Stylus Scan 2500

Revision A

1.4.3 Environmental conditions

Temperature

10~35°C (operating, see figure below)

 

-20~60°C (non-operating, in packaging)

 

One month at 40°C

 

120 hours at 60°C

Humidity

20~80% RH (operating, without condensation, see

 

figure below)

 

5~85% RH (non-operating, in packaging without

 

condensation)

Resistance to shock

1 G, within one ms (operating)

 

2 G, within two ms (non-operating, in packaging)

Resistance to vibration

0.15G (operating)

 

0.50G (non-operating, in packaging)

 

90

 

 

 

 

 

 

80

 

 

 

 

 

 

70

 

 

 

 

 

 

60

 

 

 

 

 

Humidity (%)

50

 

 

 

 

 

 

40

 

 

 

 

 

 

30

 

 

 

 

 

 

20

 

 

 

 

 

 

10

 

 

 

 

 

 

10

20

27

30

35

40

Temperature (°C)

Figure 1-6. Humidity and Temperature

1.4.4 Resistance to electric noise

Static electricity

panel - 10kV

 

metal - 7kV/150pF, 150 Ω

1.4.5 Reliability

Total print volume

60,000 pages (A4, Letter)

Printhead life

4 billion dots/nozzle

Scan head

MCBF 30,000 cycles

1.4.6

Acoustic noise

Level

Approx. 46 dB (local copy with no ADF)

 

Approx. 50 dB (local copy with ADF)

 

(According to ISO7779)