EPSON Stylus Scan 2500

Revision A

SCANNER-SPECIFIC ERRORS

Table 1-18. Scanner-SPECIFIC errors

Error

 

Cause

 

Solution

 

 

 

 

 

 

 

• The lamp is broken.

 

Turn off the Stylus Scan and

 

 

• Stylus Scan turned on before

 

turn it back on. If the error does

 

 

the transportation screw was

 

not clear, service.

Fatal error

 

removed.

 

(Disposition)

 

 

• System breakdown.

 

Turn off the lamp and stop

 

 

 

 

operation. Set bit 7 of the

 

 

 

 

status byte.

 

 

 

 

 

 

 

 

 

After removing the document,

 

 

 

 

turn the Stylus Scan off and

 

 

 

 

back on, or send the ESC @

ADF paper

 

 

 

command.

 

ADF fails to eject the document.

 

Parallel I/F init: active pulse

jam

 

 

 

 

 

(Disposition)

 

 

 

 

 

 

 

 

Turn off the lamp and stop

 

 

 

 

operation. Set bit 7 of the

 

 

 

 

status byte.

 

 

 

 

 

 

 

Unidentified command detected.

 

 

 

 

(Disposition)

 

 

Command

 

The scanner sent a NACK signal

 

Send a correct command to

 

and is waiting for the next

 

error

 

command. If an incorrect

 

clear the error.

 

 

command or parameter is

 

 

 

 

received, it is disregarded and the

 

 

 

 

previous value is maintained.

 

 

 

 

 

 

 

ADF cover

 

ADF cover open

 

Close the cover.

open

 

 

 

 

 

 

 

 

 

 

 

Maintenance

 

Maintenance cover open

 

Close the cover.

cover open

 

 

 

 

 

 

 

 

 

 

 

1.9 Options

The optional Auto Document Feeder and optional Transparency Unit designed for use with the GT-7000 scanner may also be used with the EPSON Stylus Scan 2500 under the following restrictions.

1.9.1 Local Copy

ADF

If a document is loaded in the ADF tray, the Stylus Scan loads and scans that document.

If a document remains on the document glass, a copy is not produced normally.

Even if multiple copies are selected, the Stylus Scan ignores this setting and produces only one copy per document sheet.

TPU

The TPU cannot be used in Local Copy mode. The Stylus Scan ignores the TPU in this mode.

1.9.2 Scanning

ADF

Same as the GT-7000.

TPU

If the Stylus Scan receives transparency scanning commands, it will turn on the TPU lamp and scan the transparency after the warm-up period. The Stylus Scan ignores the ADF in this mode. After scanning, the TPU lamp remains on until the TPU is turned off or until the Stylus Scan receives reflective document scanning commands.

If the Stylus Scan receives reflective document scanning commands, it will scan the document normally.

Product Description