4.6.7 Removing the PE Paper Detector Assembly

1.Remove the housing. (Refer to Section 4.3.)

2.Release two fixed hooks securing the PE detector assembly from the back of the frame and remove the PE detector assembly, sliding it upward. Remove the PE board assembly and PE lever, if necessary.

CH E CDuringK assembly, make sure that the tip (sensor part) of P O I NtheTdetector lever is in the hole of paper guide assembly.

After releasing two hooks, remove the PF paper detector assmebly, sliding it upward.

PE Holder

This side should be installed on the frame.

PE Board Assembly

(From back side of

the frame)

PE Lever

Torsion Spring 0.22

Figure 4-16. Removing the PE Detector Assembly