SCANNER INITIALIZATION

There are three initialization methods.

1.Hardware initialization

The scanner initializes when turned on.

When the scanner initializes, the following actions are performed. Initialize scanner mechanism

Clear input/output data buffer Set default values

2.Operator initialization

The scanner initializes when it recognizes the -INIT signal (negative pulse) from the parallel interface.

When the scanner initializes, the following actions are performed.

Clear input/output data buffer

Set default values

3.Software initialization

The ESC@ command also initializes the scanner.

When the scanner initializes, the following actions are performed.

￿

Clear input/output data buffer

Set default values

1.7 Settings Menu

Enter the settings menu mode by holding down the Quality and B&W/Color buttons. Settings are saved when the power is turned off.

Table 1-16. Settings Menu

Button

Function

LCD

 

 

 

 

 

Hold Quality + B&W buttons for three

Quality

Change modes

seconds

Menu Mode

B&W/

Copy<-> Settings Menu

Color

After two seconds

 

 

 

BottomMargin:14/3mm

 

 

 

 

 

Cycles through the menus below:

 

 

BottomMargin:14/3mm

Copies

Change menu in

PaperSize:Metric/US

+/-

Settings Menu mode

Lang:Eng Ger Fr Ital Span Port

 

 

Set Factory Default

 

 

Status Sheet Print

 

 

 

 

Executes menu or

Lang: Eng Ger Fr Ital Span Port

Copy

Press copy to change to next

selects item

 

Lang: Ger Fr Ital Span Port Eng

 

 

 

 

 