SCANNER INITIALIZATION

There are three initialization methods.
1. Hardware initialization
The scanner initializes when turned on.
When the scanner initializes, the following actions are performed.
Initialize scanner mechanism
Clear input/output data buffer
Set default values
2. Operator initialization
The scanner initializes when it recognizes the -INIT signal (negative pulse)
from the parallel interface.
When the scanner initializes, the following actions are performed.
Clear input/output data buffer
Set default values
3. Software initialization
The ESC@ command also initializes the scanner.
When the scanner initializes, the following actions are performed.
Clear input/output data buffer
Set default values
1.7 Settings Menu
Enter the settings menu mode by holding down the Quality and B&W/Color
buttons. Settings are saved when the power is turned off.

Table 1-16. Settings Menu

Button Function LCD
Quality
B&W/
Color
Change modes
Copy<-> Settings Menu
Hold Quality + B&W buttons for three
seconds
Menu Mode
After two seconds
BottomMargin:14/3mm
Copies
+/- Change menu in
Settings Menu mode
Cycles through the menus below:
BottomMargin:14/3mm
PaperSize:Metric/US
Lang:Eng Ger Fr Ital Span Port
Set Factory Default
Status Sheet Print
Copy Executes menu or
selects item
Lang: Eng Ger Fr Ital Span Port
Press copy to change to next
Lang: Ger Fr Ital Span Port Eng