EPSON Stylus Scan 2500

Revision A

Table 3-9. Carriage Unit does not operate (cont.)

Cause

 

Step

 

Checkpoint

 

Finding

 

Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

Disconnect the connector

 

 

 

 

 

 

 

 

CN6 on the control board,

 

 

 

 

 

 

 

 

then using the tester,

 

 

 

 

 

 

 

 

check the coil resistance

 

No

 

Replace the CR

 

 

 

 

between Pin2 and 4 and

 

 

motor.

 

 

 

 

 

 

 

 

 

 

 

between Pin1 and 3. Is the

 

 

 

 

 

 

 

 

resistance of 2 points

 

 

 

 

 

 

 

 

about 6.2Ω?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If any motor coil is

 

 

 

 

CR Motor is

 

 

 

shorted, check the CR

 

 

 

 

 

 

 

motor drive circuit in the

 

 

 

 

broken

 

3

 

 

 

 

 

 

 

order below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.)Set the tester on Ohms.

 

 

 

 

 

 

 

 

2.)Place the (-) lead of the

 

 

 

 

 

 

 

 

tester on any of Pins 1,2, 3

 

No

 

Replace the

 

 

 

 

or 4 for CN1 on the control

 

 

power board.

 

 

 

 

 

 

 

 

 

 

 

hoard.

 

 

 

 

 

 

 

 

3.)Place the (+) lead of the

 

 

 

 

 

 

 

 

tester on Pin 6/7 for CN4

 

 

 

 

 

 

 

 

on the control board.

 

 

 

 

 

 

 

 

With the scanner off, does

 

 

 

 

 

 

 

 

the meter show “”?

 

 

 

 

 

 

 

 

 

 

 

 

 

Control

 

 

 

 

 

 

 

Replace the

board is

 

4

 

---

 

---

 

 

 

 

 

control board.

broken.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3-10. Carriage unit crashes into frame

Cause

 

Step

 

 

Checkpoint

 

Finding

 

Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the signal

 

 

 

 

 

 

 

 

level.

 

 

 

 

 

 

 

 

Check the

 

 

 

 

 

 

 

 

 

signal/status

 

 

 

Replace the CR

 

 

 

 

 

level between

 

 

 

 

 

 

 

 

 

 

 

home position

CR home position

 

 

 

 

C(+) and E(-) for

 

 

 

 

1

 

 

 

--

 

sensor(PC1/PC2)

sensor is broken.

 

 

 

PC2.

 

 

 

 

 

 

 

 

 

on the control

 

 

 

 

H(about 4.5V)/

 

 

 

 

 

 

 

 

 

 

board.

 

 

 

 

when PC1-PC2 is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

closed.

 

 

 

 

 

 

 

 

L(0.3V)/when PC1

 

 

 

 

 

 

 

 

-PC2 is opened.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3-11. The lamp does not light up.

Cause

 

Step

 

Checkpoint

 

Finding

 

Solution

 

 

 

 

 

 

 

 

 

Connector CN5 on

 

 

 

Is the connector CN5

 

 

 

Connect CN5

the control board is

 

1

 

on the control board

 

Yes

 

 

 

 

 

properly.

disconnected.

 

 

 

disconnected?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector CN1 or

 

 

 

Is the connector CN1

 

 

 

 

CN2 on the CCD

 

 

 

 

 

 

Connect CN1 or

 

2

 

or CN2 on the CCD

 

Yes

 

board

 

 

 

 

2 properly.

 

 

 

board disconnected?

 

 

 

disconnected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp is not

 

 

 

Is the lamp

 

 

 

 

connected properly

 

3

 

connected properly

 

No

 

Connect the

on the inverter

 

 

on the inverter

 

 

lamp properly.

 

 

 

 

 

 

board.

 

 

 

board?

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp is broken.

 

4

 

Does the lamp light

 

Yes

 

Replace the

 

 

after it is replaced?

 

 

lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter board is

 

 

 

Does it operate

 

 

 

Replace the

 

5

 

properly after

 

Yes

 

broken.

 

 

 

 

inverter board.

 

 

 

replacing it?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control board is

 

6

 

---

 

---

 

Replace the

broken.

 

 

 

 

control board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Troubleshooting

Scanner Troubleshooting

72

Page 72
Image 72