EPSON Stylus Scan 2500

Revision A

5.Remove one screw (CBS 3x6) securing the power-button board and one screw (CBS 4x6) securing the upper frame..

Cable protector

Remove two

screws.

6.Pull the upper frame a little to the center and front of the Stylus Scan. Remove the cable protector and cables. Remove the power board frame.

4.3.8 Removal of the B102 PSB/PSE Board

1.Remove the rear cover and top cover as described in “Removing the Housing” on page 82.

2.Remove the side covers as described in “Removing the side covers” on page 84.

3.Remove the scanner support frame as described in “Removing the scanner support frame” on pag e84.

4.Remove the paper eject assembly as described in “Removing the paper eject assembly” on page 85.

5.Remove the power supply board upper frame as described in “Removing the power supply board upper frame” on page 86.

6.Disconnect the power cable leading to the B102 MAIN board, and remove three screws (CBS 3x6).

Remove one connector and three screws.

Disassembly & Assembly

Removing the Housing

87

Page 88
Image 88
Epson Scan 2500 service manual Removal of the B102 PSB/PSE Board, Cable protector Remove two Screws