EPSON Stylus Scan 2500

Revision A

4.7.1.2 Removing the scanner power supply board

1.

Remove the scanner cover and lamp as described above.

2.

Remove one screw (CBP 3x8 with flange).

3.

Remove one connector CN1.

4.7.1.3Removing the scanner assembly from the scanner guide shaft

1. Using pliers, remove one spring..

4. Remove the power supply board.

1)Remove spring here.

3)Remove the FFC.

5)Slide the left carriage guide frame

to the right to

release the belt.

4) Remove

2) Remove twocarriage belt clip. screws.

2.Remove two screws (CBS 3x6).

3.Turn the scanner vertical and remove the FFC.

4.Using pliers, remove the carriage belt clip.

5.Slide the left carriage guide frame slightly to the right.

6.While rotating the belt around the pulley, remove the belt from the driven pulley.

7.While supporting the scanner with one hand, slide the left carriage guide frame to the left until the carriage guide shaft comes free.

8.Slide the scanner assembly off the carriage guide shaft.

Disassembly & Assembly

Disassembly of the Scanner Mechanism

111

Page 112
Image 112
Epson Scan 2500 Removing the scanner power supply board, Removing the scanner assembly from the scanner guide shaft