MODELS: CGN10A AND CGN6

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion must be provided. Refer to page 3 of this manual.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS Blue Flame VENT-FREE Natural GAS HeaterCGN10A and CGN6 Natural GAS Heater Safety InformationProduct Identification Product FeaturesFresh AIR for Combustion and Ventilation Local CodesUnusually Tight Construction Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items Installing to WallInstalling Heater to Wall Check GAS TypeAttaching to wall anchor method Installing Bottom Mounting ScrewPlacing Heater On Mounting Screws Removing Front Panel Of HeaterGas Connection Connecting to GAS SupplyPressure Testing Heater GAS Connections Pressure Testing GAS Supply Piping SystemFor Your Safety Read Before Lighting Checking GAS ConnectionsLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Replacement Parts SpecificationsTechnical Service Service PublicationsHeater Exploded View Illustrated Parts ListODS/PILOT Parts Available not Shown FBD Parts Centrals101870 Keep this Warranty Warranty Information

CGN6, CGN10A specifications

Desa CGN10A and CGN6 are two innovative models in the Desa line of heating appliances, combining cutting-edge technology with user-friendly features designed to enhance the heating experience in a variety of settings. These appliances are particularly noted for their versatility and efficiency, making them suitable for both residential and commercial applications.

The Desa CGN10A stands out with its impressive heating capacity, providing an excellent solution for larger spaces. It is engineered with advanced venting technology that ensures optimal airflow, allowing the unit to quickly and evenly distribute heat throughout the room. This model features an adjustable thermostat and fan settings, enabling users to customize their heating experience according to their specific needs. The eco-friendly design reduces energy consumption while maintaining superior performance, making it a smart choice for environmentally conscious consumers.

On the other hand, the Desa CGN6 is perfect for smaller areas or more limited spaces. Despite its compact size, it does not compromise on heating power or efficiency. This model utilizes a highly efficient combustion system that maximizes fuel usage, translating into lower operational costs for users. Additionally, its lightweight and portable design makes it suitable for various settings, whether it's in a workshop, garage, or even outdoor gatherings.

Both models are equipped with safety features that ensure peace of mind during operation. They include automatic shut-off functions and safety sensors that detect issues such as overheating or improper venting. Furthermore, the appliances are designed with user accessibility in mind, featuring intuitive controls and easy-to-read displays that simplify the operating process.

In terms of aesthetics, both the CGN10A and CGN6 boast sleek designs that can seamlessly integrate into a range of interior styles. The durable construction ensures longevity, making these models a reliable investment for years to come.

In conclusion, Desa CGN10A and CGN6 models exemplify the perfect blend of efficiency, technology, and design. With their responsive heating capabilities, user-friendly features, and emphasis on safety, they stand out as leaders in the heating appliance market, catering to diverse user needs while prioritizing sustainability.