Desa CGN10A, CGN6 Lighting Instructions, To Turn OFF GAS To Appliance, Manual Lighting Procedure

Page 10

CGN10A AND CGN6

NATURAL GAS HEATER

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information page 9, column 3.

2.Make sure manual shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

Ignitor Button

 

Control Knob

 

PILOT

OFF

 

 

HIGH

IGNITOR

LOW

Figure 15 - Control Knob In The OFF Position

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of column 3, page 9. If you don’t smell gas, go to the next step.

5.Press in control knob and turn coun-

terclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 15).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 12 through 14. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8.Turn control knob counterclockwise

to the HIGH position. The main burner should light. Set control knob to any heat level between HIGH and LOW. To turn control knob from HIGH to a lower setting, press in the control knob and turn counterclock-

wise .

Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 16 - Pilot

CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the PILOT position.

2.Press in control knob and turn clock-

wise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

1.Turn control knob clockwise to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 7).

2.Follow steps 1 through 5 under Light- ing Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after pilot is lit. After 30 sec- onds, release control knob.

5.Replace front panel.

10

101870

Image 10
Contents Blue Flame VENT-FREE Natural GAS Heater What to do if YOU Smell GASSafety Information CGN10A and CGN6 Natural GAS HeaterFresh AIR for Combustion and Ventilation Product FeaturesProduct Identification Local CodesUnusually Tight Construction Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Heater to Wall Installing to WallInstallation Items Check GAS TypePlacing Heater On Mounting Screws Installing Bottom Mounting ScrewAttaching to wall anchor method Removing Front Panel Of HeaterConnecting to GAS Supply Gas ConnectionFor Your Safety Read Before Lighting Pressure Testing GAS Supply Piping SystemPressure Testing Heater GAS Connections Checking GAS ConnectionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Shutting Off HeaterCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Technical Service SpecificationsReplacement Parts Service PublicationsHeater Exploded View Illustrated Parts ListODS/PILOT Parts Available not Shown Parts Centrals FBD101870 Warranty Information Keep this Warranty

CGN6, CGN10A specifications

Desa CGN10A and CGN6 are two innovative models in the Desa line of heating appliances, combining cutting-edge technology with user-friendly features designed to enhance the heating experience in a variety of settings. These appliances are particularly noted for their versatility and efficiency, making them suitable for both residential and commercial applications.

The Desa CGN10A stands out with its impressive heating capacity, providing an excellent solution for larger spaces. It is engineered with advanced venting technology that ensures optimal airflow, allowing the unit to quickly and evenly distribute heat throughout the room. This model features an adjustable thermostat and fan settings, enabling users to customize their heating experience according to their specific needs. The eco-friendly design reduces energy consumption while maintaining superior performance, making it a smart choice for environmentally conscious consumers.

On the other hand, the Desa CGN6 is perfect for smaller areas or more limited spaces. Despite its compact size, it does not compromise on heating power or efficiency. This model utilizes a highly efficient combustion system that maximizes fuel usage, translating into lower operational costs for users. Additionally, its lightweight and portable design makes it suitable for various settings, whether it's in a workshop, garage, or even outdoor gatherings.

Both models are equipped with safety features that ensure peace of mind during operation. They include automatic shut-off functions and safety sensors that detect issues such as overheating or improper venting. Furthermore, the appliances are designed with user accessibility in mind, featuring intuitive controls and easy-to-read displays that simplify the operating process.

In terms of aesthetics, both the CGN10A and CGN6 boast sleek designs that can seamlessly integrate into a range of interior styles. The durable construction ensures longevity, making these models a reliable investment for years to come.

In conclusion, Desa CGN10A and CGN6 models exemplify the perfect blend of efficiency, technology, and design. With their responsive heating capabilities, user-friendly features, and emphasis on safety, they stand out as leaders in the heating appliance market, catering to diverse user needs while prioritizing sustainability.