Desa CGN10A, CGN6 Determining FRESH-AIR Flow for Heater Location, Unusually Tight Construction

Page 4

CGN10A AND CGN6

NATURAL GAS HEATER

FRESH AIR FOR COMBUSTION AND VENTILATION

Continued

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where: a.walls and ceilings exposed to

the outside atmosphere have a continuous water vapor re- tarder with a rating of one perm (6x10-11kg per pa-sec-m2) or less with openings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are ap- plied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceil- ing joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 5.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Heater Location.

Confined and Unconfined Space

The National Fuel Gas Code (ANSIZ2123.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in-

stalled*, through openings not furnished with doors, are considered a part of the unconfined space.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height =

______ cu. ft. (volume of space)

Example: Space size

20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) =

2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/ Hr the space can support.

_____ (volume of space) ÷ 50 cu. ft. =

(Maximum Btu/Hr the space can sup- port)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can sup- port)

3.Add the Btu/Hr of all fuel burning ap- pliances in the space.

Vent-free heater _________ Btu/Hr

Gas water heater* ________ Btu/Hr

Gas furnace ____________ Btu/Hr

Vented gas heater ________ Btu/Hr

Gas fireplace logs ________ Btu/Hr

Other gas

appliances* + ___________ Btu/Hr

Total = ________________ Btu/Hr

Example: Gas water heater

44,000 Btu/Hr

Vent-free heater + 6,000 Btu/Hr

Total

= 50,000 Btu/Hr

*Do not include direct-vent gas appli- ances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

__________ Btu/Hr (maximum the

space can support)

__________ Btu/Hr (actual amount of

Btu/Hr used)

Example: 46,100 Btu/Hr (maximum the space can support)

50,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a con- fined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventila- tion grills between rooms. See Ventila- tion Air From Inside Building, page 5.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 5.

C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide ad- equate combustion and ventila- tion air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3 or applicable local codes.

4

101870

Image 4
Contents Blue Flame VENT-FREE Natural GAS Heater What to do if YOU Smell GASSafety Information CGN10A and CGN6 Natural GAS HeaterProduct Features Product IdentificationFresh AIR for Combustion and Ventilation Local CodesUnusually Tight Construction Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing to Wall Installation ItemsInstalling Heater to Wall Check GAS TypeInstalling Bottom Mounting Screw Attaching to wall anchor methodPlacing Heater On Mounting Screws Removing Front Panel Of HeaterConnecting to GAS Supply Gas ConnectionPressure Testing GAS Supply Piping System Pressure Testing Heater GAS ConnectionsFor Your Safety Read Before Lighting Checking GAS ConnectionsManual Lighting Procedure Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off HeaterCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Specifications Replacement PartsTechnical Service Service PublicationsHeater Exploded View Illustrated Parts ListODS/PILOT Parts Available not Shown Parts Centrals FBD101870 Warranty Information Keep this Warranty

CGN6, CGN10A specifications

Desa CGN10A and CGN6 are two innovative models in the Desa line of heating appliances, combining cutting-edge technology with user-friendly features designed to enhance the heating experience in a variety of settings. These appliances are particularly noted for their versatility and efficiency, making them suitable for both residential and commercial applications.

The Desa CGN10A stands out with its impressive heating capacity, providing an excellent solution for larger spaces. It is engineered with advanced venting technology that ensures optimal airflow, allowing the unit to quickly and evenly distribute heat throughout the room. This model features an adjustable thermostat and fan settings, enabling users to customize their heating experience according to their specific needs. The eco-friendly design reduces energy consumption while maintaining superior performance, making it a smart choice for environmentally conscious consumers.

On the other hand, the Desa CGN6 is perfect for smaller areas or more limited spaces. Despite its compact size, it does not compromise on heating power or efficiency. This model utilizes a highly efficient combustion system that maximizes fuel usage, translating into lower operational costs for users. Additionally, its lightweight and portable design makes it suitable for various settings, whether it's in a workshop, garage, or even outdoor gatherings.

Both models are equipped with safety features that ensure peace of mind during operation. They include automatic shut-off functions and safety sensors that detect issues such as overheating or improper venting. Furthermore, the appliances are designed with user accessibility in mind, featuring intuitive controls and easy-to-read displays that simplify the operating process.

In terms of aesthetics, both the CGN10A and CGN6 boast sleek designs that can seamlessly integrate into a range of interior styles. The durable construction ensures longevity, making these models a reliable investment for years to come.

In conclusion, Desa CGN10A and CGN6 models exemplify the perfect blend of efficiency, technology, and design. With their responsive heating capabilities, user-friendly features, and emphasis on safety, they stand out as leaders in the heating appliance market, catering to diverse user needs while prioritizing sustainability.